Manual

The EdgeAccess Universal Chassis System
2361 Modem Users Manual
3-2
Configuration alarm will allow data to pass through, although it may not be decipherable at the
other end.
CLS: Composite Loss of Signal LED
Solid Red Local Modem detects loss of sync
Flashing Red Remote modem detects loss of sync
TST: Test Mode LED
Solid Yellow The local modem is in local or local bi-directional loopback mode
Flashing Yellow The remote modem is in local or local bi-directional loopback
mode
Solid Red Errors received from continuous BERT test (or the remote
loopback with BERT performed from the local modem) resulted in
errors
Flashing Red Remote is receiving errors from Local BERT
Reset Button:
Resets power and does not affect the payload of the modem data in a nonredundant setup.