Instruction Manual
Table Of Contents
- General Safety Considerations
- Chapter 1 Chapter 1Overview
- Chapter 2 Chapter 2Installation and Setup
- Chapter 3 Chapter 3Electrical Data Interfaces
- 3.1 L130: Configurable EIA-232/423/530/P53/449/V35
- 3.2 P53 Interface for the L130
- 3.3 L131: EIA-422, DC-37 With Control Signals
- 3.4 L132: EIA-422, TwinAx
- 3.5 L133: TTL, BNC
- 3.6 L134, L135, L136, L137: T1 and E1
- 3.7 L138: EIA-422, DC-37 Without Control Signals
- 3.8 L139: T88
- 3.9 Operating Modes and Transmit/Receive Timing
- Chapter 4 Chapter 4Software Management
- 4.1 VT100 Terminal Emulation
- 4.2 PC Configuration for Terminal Operation
- 4.3 Management User Interface
- 4.4 2370 Main Menu
- 4.5 System Configuration
- 4.6 Hardware Configuration
- 4.7 Functional Configuration
- 4.8 Trap Configuration
- 4.9 Alarm Output Configuration
- 4.10 SNMP Configuration
- 4.11 Host Table
- 4.12 Diagnostics
- 4.13 Interface Status
- 4.14 Link Error Counters
- 4.15 System Alarms
- 4.16 Utilities
- 4.17 PING
- 4.18 Software Upgrade
- Chapter 5 Chapter 5Troubleshooting
- Chapter 6 Chapter 6Specifications
L135 T1
DA-15
L136 E1
RJ-48C
L137 E1
DA-15
L138
EIA 422 clock & data only
DC37
L139 MIL 188-114A
5 Twinax connectors
Power Requirement:
48VDC, 10W max
EIA-561 Signal TRM MDM RS232 DE9
1 RI ← ← 6
2 DCD/CD → ← 1
3 DTR ← → 4
4 SG COM COM 5
5 RD
→ ←
2
6 TD
← →
3
7 CTS → ← 8
8 RTS ← → 7
NOTE: To manage a modem installed in a 1050 or UCS1001 chassis the above pin out is required to
connect to a PC serial port. The front panel switch must be set to TRM. Only the highlighted
conductors are needed. An adapter can be purchased from Canoga Perkins.
Part number 6731550. RI is tied low through a 10k resistor
Table 22. EIA-561 Pin out
6.3 Physical / Environmental
Dimensions: 7.9" H x 1.0" W x 10.4" D (201 mm x 25 mm x 264 mm)
Weight: 0.9 lbs (0.41 kgs)
Operating Environment:
Temperature 0 to 50° C
Humidity Up to 90% (non-condensing)
6.4 Regulatory Compliance
• ETL, cETL & LVD (UL 60950 CAN/CSA C22.2 No. 60950, EN/IEC 60950)
• EMC Directive (EN55022 Class A, EN 55024, EN 61000-3-2/-3-3)
• CE Mark
• FCC Part 15 Subpart B Class A (U.S.)/ICES-003 (CAN)
• VCCI Class A (Japan)
• C-Tick (AS/NZS 3548 - Australia)
• CDRH CFR21/IEC 60825-1 (Laser Safety)
• NEBS Level 3 Certified & Tested
Model 2370 User Manual
6-2