Model 6703 CWDM Transponder User Manual
EdgeAccess Universal Chassis System CAUTION! This product may contain a laser diode operating at a wavelength of 1300 nm - 1600 nm. Use of optical instruments (e.g., collimating optics) with this product may increase eye hazard. Use of controls or adjustments, or performing procedures other than those specified herein may result in hazardous radiation exposure. Under normal conditions, the radiation levels emitted by this product are under Class 1 limits in 21 CFR Chapter 1, Subchapter J.
EdgeAccess Universal Chassis System NOTICE Canoga Perkins has prepared this users manual for use by customers and Canoga Perkins personnel as a guide for the proper installation, operation and/or maintenance of Canoga Perkins equipment. The drawings, specifications and information contained in this document are the property of Canoga Perkins and any unauthorized use or disclosure of such drawings, specifications and information is prohibited.
EdgeAccess Universal Chassis System Table of Contents Chapter 1 Overview .................................................................................................1-1 Chapter 2 Hardware Installation and Operation .................................................2-1 2.1 2.2 Install the Module...................................................................................................................2-1 Front Panel LEDs ...........................................................................
EdgeAccess Universal Chassis System List of Figures Figure 1. 6703 Wavelength Converter Function................................................................................ 1-1 Figure 2. Front Panel, 6703 With Local Port Interface Options ........................................................ 1-2 Figure 3. General Screen Navigation................................................................................................. 3-2 Figure 4. Main Menu ..................................................
EdgeAccess Universal Chassis System Chapter 1 Overview The 6703 Coarse Wavelength Division Multiplexer (CWDM) Transponder converts optical signals from standard optical interfaces to Single mode CWDM wavelengths for use with a CWDM Multiplexer/Demultiplexer (Mux/Demux). The 6703 is protocol transparent and uses Avalanche Photo Diodes and Clock Data Recovery (CDR) to increase receiver sensitivity at high data rates.
EdgeAccess Universal Chassis System The 6703 front panel, shown in Figure 2, includes: • • • • • • • Status LED Reset button TRM/MDM switch: Selects terminal emulation or a dial-up modem EIA-232 (Console) port with RJ-48 connector: Provides software management access Local port with Rx/Tx LEDs: Receives from/transmits to the local equipment; LEDs show port status; optical interface can be fixed SC at 1310 nm (6703-0003) or SFP (6703-0000) Remote port with Rx/Tx LEDs: Receives from/transmits to the 6004 or
EdgeAccess Universal Chassis System Chapter 2 Hardware Installation and Operation This section describes how to install a 6703 in a UCS 1000 or 1001 chassis or in a Model 1040 or 1050 standalone enclosure. 2.1 Install the Module You can install the 6703 module in any slot from slot 1 to 15 in the UCS 1000, in either slot in a UCS 1001, or in a Model 1040 or 1050 standalone enclosure. To install the module, follow these steps: 1. Unpack and inspect all components.
EdgeAccess Universal Chassis System 8. If you will directly manage the 6703, such as in a UCS 1001 or 1050 standalone enclosure, follow these steps: a. Plug the RJ-48 serial cable into the console port on the front of the 6703. b. Plug the other end of the serial cable into an RJ-48 to DE-9 adapter, then into the modem or the COM port on the PC. c. Set the TRM/MDM switch to TRM for local management through a local terminal or to MDM for remote management through a dial-up modem. 9.
EdgeAccess Universal Chassis System LED Status LCDR/SC and RCDR/SC Off Indicates Clock Recovery and SpeedCop are disabled Green Clock Recovery is enabled and locked and/or SpeedCop is enabled and within range Amber Clock Recovery is disabled; SpeedCop detects a violation Red Clock Recovery detects a loss of sync; SpeedCop is disabled Blinking green/amber Clock Recovery is enabled and locked; SpeedCop detects a violation Blinking red/amber Clock Recovery detects a loss of sync; SpeedCop detects
EdgeAccess Universal Chassis System 2-4 CWDM Transponder Model 6703
EdgeAccess Universal Chassis System Chapter 3 Software Management The standard management package is the VT100 Terminal Emulation, which you can access through a Telnet session, HyperTerminal or similar terminal emulation software, or CanogaView. You can run up to two management sessions at one time. 3.1 Use VT100 Terminal Emulation You can access the VT100 terminal emulation management functions through the console port, a dialup modem, or the Domain Management Module (DMM) for the domain.
EdgeAccess Universal Chassis System 3.2 Management User Interface The Management User Interface for the system provides screens for setup, monitoring, and diagnostics. These sections discuss the screens for the system, using a Telnet session for access. 3.2.1 General Screen Format A typical 6703 screen includes standard screen descriptions and references. See Figure 3. All screens use a common method for navigation.
EdgeAccess Universal Chassis System 3.2.
EdgeAccess Universal Chassis System 3.4 System Configuration Menu The System Configuration menu provides access to most configuration options for the 6703. To access the System Configuration menu, follow theses steps: 1. From the Main Menu, type 1, "System Configuration," and press . The System Configuration menu appears. 2. To return to the Main menu, press . SYSTEM CONFIGURATION 1) 2) 3) 4) Hardware Description Trap Configuration Alarm Output Configuration SNMP configuration Figure 5.
EdgeAccess Universal Chassis System HARDWARE DESCRIPTION Chassis Type Chassis/Slot 5U UCS 1000 5/4 Model Type Hardware Rev. Serial Number 6703-0000 UNIV OC48 TRANSPONDER SFP/SFP A1 20030485762 Power Supply Pri Power Supply Sec Fan Status Alarm Relay Inputs DC Non Isolated AC 120/240 OK N/A Figure 6.
EdgeAccess Universal Chassis System TRAP CONFIGURATION 1) 2) 3) 4) 5) 6) 7) 8) 9) Master Trap Control Diagnostics Trap Cold Start Traps Power/Fan Malfunction Traps Alarm Input Traps Receive Level Traps SpeedCop Violation Traps CDR Unlock Traps SFP Transceiver Traps Enabled Enabled Enabled Enabled Enabled Local Port Remote Port Enabled Enabled Enabled N/A Enabled Enabled Enabled Enabled Figure 8. Trap Configuration Menu 3.4.
EdgeAccess Universal Chassis System Table 3.
EdgeAccess Universal Chassis System Table 4.
EdgeAccess Universal Chassis System HOST TABLE Managing Access Trap Trap Managing Access Trap Trap Host Level Community Port Host Level Community Port ----------------------------------- ---------------------------------172.16.142.20 4 public 162 172.16.142.3 4 public 162 192.0.0.3 4 public 162 Add or Delete a host entry (1=Add, 2=Delete from table): Figure 11. Host Table Screen 3.
EdgeAccess Universal Chassis System CONFIGURATION/STATUS 1) Clock Data Recovery/SpeedCop: CDR Local & Remote Rx CDR Rate: Auto Detect (1250 Mbps detected) Local Port: TX Status SpeedCop Status CDR Status RX Level ON Disabled N/A OK 2) TX Control 3) Loopback ON OFF Remote Port: TX Status SpeedCop Status CDR Status RX Level SFP Xcvr Status ON Disabled Locked -21.2 dBm (OK) Present 4) TX Control On 5) Loopback OFF 6) Dual RX Control N/A Figure 12. Configuration/Status Screen Table 5.
EdgeAccess Universal Chassis System Table 6.
EdgeAccess Universal Chassis System 3.6 Error Counters The Error Counters screen reports errors that occur on the 6703 link. See Figure 14 and Table 7. To view the link errors, follow these steps: 1. From the Main menu type 3, "Error Counters," and press . The Error Counters screen appears. 2. To reset the timer and counters, press . 3. To return to the Main Menu, press .
EdgeAccess Universal Chassis System Table 8.
EdgeAccess Universal Chassis System 3.8 Upgrading the Software Each 6703 has two flash memory banks for storing firmware: • • Active Flash Memory holds the software in current use Inactive Flash Memory holds the software upgrade after downloading; can be swapped with the firmware in active memory Use the Software Upgrade report and menu screen to check the current version of the firmware and upgrade it, if necessary. All 6703 modules within the system must run the same version of software.
EdgeAccess Universal Chassis System 3. Log on to www.canoga.com and check that a newer version of the software is available. 4. Click Download. 5. Scroll to the listing for the 6703 software. 6. If this version is newer than your current version, click the file name to start the download process. 7. At the File Download window, select Save this Program to Disk. 8. At the Save As dialog, save the download to the root directory of your server. 3.8.
EdgeAccess Universal Chassis System 3.9 SNMP - TCP/IP You can use TCP/IP options such as TFTP, Telnet, PING and SNMP agents with the 6703 console port over SLIP or PPP. You must enable TCP/IP separately. 3.9.1 Set Up a Dial-up Connection When the 6703 boots up, the serial port defaults to VT100 terminal mode for access. However, to use Telnet, TFTP or SNMP applications, you must switch the serial port to SLIP/PPP mode. To set up a Dial-Up Connection, follow these steps: 1.
EdgeAccess Universal Chassis System 2. Save the Notepad document with a .SCP file extension in the folder where the Dialup Connection application looks for scripts. The script will be available in the Dialup script menu. This file is typically in the Windows\System32\ras\ folder. 3. To run the script, reach the Phonebook Entry dropdown menu and select either the PPP or the SLIP script. 3.9.
EdgeAccess Universal Chassis System 3-18 CWDM Transponder Model 6703
EdgeAccess Universal Chassis System Chapter 4 6703 Specifications and Models 4.11 Specifications Physical Dimensions: 7.9" H x 1.0" W x 10.4" D (201 mm x 25 mm x 264 mm) Weight: 0.92 lb (0.417 kg) Operating Temperature: 0 to 50° C (32 to 122° F) Operating Humidity: Up to 95% (non-condensing) MTBF: 6703-0000: 174,978 hours (30.2 years) 6703-0003: 219,713 hours (25 years) Power Requirements: 9.
EdgeAccess Universal Chassis System Table 9. EIA Interface Pinout Signal Pin Switch at MDM Switch at TRM DCD 1 To module From module RXD 2 To module From module TXD 3 From module To module DTR 4 From module To module DSR 6 To module From module RTS 7 From module To module CTS 8 To module From module RI 9 To module From module 4.
EdgeAccess Universal Chassis System Appendix A Warranty Information Current Warranty information is available on-line in the Client Login Area of the Canoga Perkins web site (www.canoga.com) or by contacting Technical Support at 800-360-6642 (voice) or fiber@canoga.com (email).
CANOGA PERKINS CORPORATION 20600 Prairie Street Chatsworth, California 91311-6008 USA Phone: (818) 718-6300 FAX: (818) 718-6312 Web Site: www.canoga.com Email: fiber@canoga.