9161 Network Interface Device User Manual
CAUTION! This product may contain a laser diode operating at a wavelength of 1300nm - 1600nm. Use of optical instruments (e.g., collimating optics) with this product may increase eye hazard. Use of controls or adjustments, or performing procedures other than those specified herein may result in hazardous radiation exposure. Under normal conditions, the radiation levels emitted by this product are under Class 1 limits in 21 CFR Chapter 1, Subchapter J.
NOTICE Canoga Perkins has prepared this users manual for use by customers and Canoga Perkins personnel as a guide for the proper installation, operation and/or maintenance of Canoga Perkins equipment. The drawings, specifications and information contained in this document are the property of Canoga Perkins and any unauthorized use or disclosure of such drawings, specifications and information is prohibited.
Table of Contents Chapter 1 Overview .................................................................................................1-1 Chapter 2 Set-up and Installation ..........................................................................2-1 2.1 2.2 Install the 9161 ........................................................................................................................2-1 Measure Fiber Link Attenuation and Transmit Power ............................................................
Chapter 5 Maintenance and Troubleshooting ...................................................... 5-1 5.1 General Maintenance .............................................................................................................. 5-1 5.2 Manage Cable Links ............................................................................................................... 5-1 5.3 Check Optical Power Levels...................................................................................................
List of Figures Figure 1. The 9161 Front Panel..........................................................................................................1-1 Figure 2. Remote Fault Signal............................................................................................................3-2 Figure 3. Link Loss Forwarding Propagation.....................................................................................3-3 Figure 4. General Screen Format.....................................................
List of Tables Table 1. 9161 Management LEDs ..................................................................................................... 3-1 Table 2. 9161 Interface LEDs ............................................................................................................ 3-2 Table 3. System Menu Option Definitions ........................................................................................ 4-4 Table 4. IP Settings Definitions .....................................................
Chapter 1 Overview The 9161 is a 2-Port 10 Gbps Network Interface Device that provides intelligent optical demarcation and terminates managed transport at the point of delivery. In addition, the 9161 offers Layer 2 statistics, remote software upgrade, remote control and monitoring, and management through CanogaView. The 9161 supports two ports that receive and transmit 10 Gigabit Ethernet data over single mode fiber (SMF) or multimode fiber (MMF) at 1310 or 1550 nm wavelength.
1-2 9161 Network Interface Device
Chapter 2 Set-up and Installation This section describes how to set up and install the 9161. Before setting up the 9161, make sure the serial cable (required to connect the chassis to a VT100 type terminal or PC) is available. 2.1 Install the 9161 The 9161 is tested and inspected before shipment from the factory. If there is obvious damage to the shipping container, contact the carrier immediately.
Cabling for the 9161 includes the serial cable to the Terminal port, the Ethernet cable for a UTP port, and the fiber optic link to the Tx and Rx ports. 5. Plug the serial cable into the SLIP or Terminal port on the rear panel and your PC. For the pinouts, see Chapter 5, Specifications. • • The EIA 232 Terminal port provides serial access to the management software. The SLIP port provides serial or modem access to the management software.
Chapter 3 User Operation This chapter describes the hardware features and functions of the 9161. 3.1 9161 Functions and Power-Up During the initial power-up sequence, all LEDs light amber. When start-up is complete, the setup and installation are correct, and data is transmitting normally across the link, the STA LED lights green and the LNK/Rx and Tx LEDs for both ports light green or blink green when they transmit or receive data. See 3.
Table 2. 9161 Interface LEDs LED Status TX RX NET 3.3 Description Off No transmission activity Green blinking Transmission activity Amber System self-test Red Port disabled; may be due to Link Loss Forwarding (LLF) Off No link Green Link established Green blinking Receiving activity Amber System self-test Red Receiving Remote Fault Off Non-network connection Green Network connection Amber System self-test Alarms The 9161 can generate Traps and Major and Minor Alarms.
3.3.2 Link Loss Forwarding When LLF is enabled, a fault on one side of the 9161 propagates to the other side to notify that device and stops signal transmission (brings down the link). See Figure 3. Set the LLF propagation to User to Extension, Extension to User, or both directions. Set this in the User Interface; see Section 4.7.
3-4 9161 Network Interface Device
Chapter 4 Management - VT-100 You can manage the system through VT100 Terminal Emulation, which is accessible by a Telnet session, HyperTerminal or similar terminal emulation software, a standard SNMP network manager, and CanogaView. 4.1 VT100 Terminal Emulation Setting up the VT100 session depends on which connection, serial port or Ethernet, you have available for access to the VT100 management program. Canoga Perkins suggests that you use HyperTerminal for your first session.
4.3 Management User Interface The Management User Interface for the 9161 provides screens for setup, monitoring, and diagnostics. You can access the screens directly by connecting to the serial port of the 9161 These sections discuss the screens for the 9161, using a Telnet session for access. 4.3.1 General Screen Format A typical screen, shown in Figure 4, includes standard descriptions and reference designations.
4.3.
4.4 9161 Main Menu The first screen is the Login Menu. If this is your initial setup and no password has been set, press at the prompt for the password. Otherwise, type your password and press . The Main Menu appears after you log in and provides access to all functions for the 9161: setup, diagnostics, and reports. See Figure 5. 1) 2) 3) 4) 5) 6) 7) MAIN MENU System Switch Configuration Port Information Reports Diagnostics Utilities Logout Figure 5. 9161 Main Menu 4.
Selection Description 5) Security Configuration Shows parameters for passwords, lockout, and logout; you can set options 6) Account Configuration Shows user account information; you can set options 7) Main Menu Returns to the Main Menu 4.5.1 System Information Screen The System Information report shows status for the fan, temperature, and power supply(s). Use this information when troubleshooting. To view the System Information screen, see Figure 7 and follow these steps: 1.
IP SETTINGS 1. 2. 3. 4. 5. 6. 7. 8. 9. Local MAC Address : 00 00 00 06 01 00 Local IP Address Subnet Mask Gateway IP Address Enable BOOTP Mode Management VLAN Id Telnet Host Verification Static ARP Table Dynamic ARP Table Main Menu : : : : : : 172.16.3.34 255.255.0.0 172.16.1.1 no 1 disabled Figure 8. IP Settings Screen Table 4.
3. To return to the IP Settings screen, press . Use the Dynamic ARP Table to view the currently assigned IP and MAC addresses for various ports. See Figure 10. IP Address 172.16.2.82 172.16.153.6 MAC ADDRESS 00-98-2C-BE-27-01 00-50-54-C3-33-41 DYNAMIC ARP TABLE Port IP Address MAC ADDRESS Port User Ext Figure 10. Dynamic ARP Table Screen To view the current addresses, follow these steps: 1. From the IP Settings screen, type 7, "Dynamic ARP Table," and press . 2.
4.5.4 Notification Destination Table Screen The Notification Destination Table screen lists information about and options to set up hosts to receive notification of traps and alarms. To access the Notification Destination Table screen, see Figure 12 and follow these steps: 1. From the System menu type 4, "Notification Settings," and press . 2.
SECURITY CONFIGURATION PASSWORD CONFIGURATION 1. Minimum Length : 0 2. Minimum Alpha Characters : 0 3. Minimum Numeric Characters : 0 4. Minimum Punctuation Characters : 0 5. Maximum Consecutive Character Types : 0 6. Maximum Same Character : 0 7. Allow username in password : Disabled 8. Password Expiration Time : 0 9. Password Reuse Count : 0 LOCKOUT/LOGOUT CONFIGURATION 10. Lockout After Failed Attempts : 0 11. Lockout Type : Hard 12. Lockout Time : 0 13. Display Lockout Message : Disabled 14.
Menu Item Description 15. Lockout Console Port Enable or disable access to the serial port 16. Inactivity Logout time Set the time, between 1 and 30 minutes, before automatic log-out with no activity; 0 = disabled 4.5.6 User Accounts Screen The User Accounts screen lists information about and options to set up system users by user name. To access the User Accounts screen, see Figure 14 and follow these steps: 1. From the System menu type 6, "Account Configuration," and press . 2.
Table 6. Switch Configuration Menu Options Menu Item Description 1. Global Spanning Tree Parameters Set the network-wide parameters 2. Multiple Spanning Tree Parameters Set and view Multiple Spanning Tree instances 3. Global Spanning Tree Report View current network-wide parameters 4. Lag Configuration View the current information for the network and port 5. VLAN Configuration Set the VLAN parameters 6. GVRP Configuration Set the GVRP parameters 7.
GLOBAL SPANNING TREE PARAMETERS 1. Admin Mode : 2. Version : 3. Configuration Name : 4. Configuration Revision : 5. Priority : 6. Hello Time (sec) : 7. Forward Delay (sec) : 8. Max Age (sec) : 9. View/Change Interface : 10. Main Menu disabled 802.1s 00-40-2A-12-34-00 0 32768 2 15 20 Figure 17. Global Spanning Tree Parameters Menu Table 7. Global Spanning Tree Parameters Menu Options Menu Item Description 1. Admin Mode Enable or disable administrator mode 2.
3. To return to the Switch Configuration menu, press . MST INSTANCE CONFIGURATION CONFIGURED MULTIPLE SPANNING TREE INSTANCES 1. 2. 3. 4. 5. View/Change Mst View Mst Status Create Mst Delete Mst Main Menu : : : : Figure 18. MST Instance Configuration Screen 4.6.3 Global Spanning Tree Report Use the Global Spanning Tree Report screen to view Global STP parameters and interface statistics and status for the 9161. See Figure 19. To access the Lag Information screen, follow these steps: 1.
10G 1 STATISTICS Port Mode Port Up Time STP BPDUs Txed STP BPDUs Rxed RST BPDUs Txed RST BPDUs Rxed MSTP BPDUs Txed MSTP BPDUs Rxed : : : : : : : : Disabled 0 day 0 hour 26 min 0 0 0 0 0 0 Figure 20.
4.6.5 VLAN Configuration Use the VLAN Configuration screen to view and set VLAN parameters for the 9161. See Figure 23. To access the VLAN Configuration screen, follow these steps: 1. From the Switch Configuration menu, type 5, "VLAN Configuration," and press . 2. At the VLAN Configuration screen, type 1 to view VLAN information and press , then follow the prompts on the screen. The VLAN Information screen appears; see Figure 24. 3.
PORT/LAG SP 1 SP 2 SP 3 SP 4 GVRP INFORMATION MODE JOIN TIMER LEAVE TIMER LEAVEALL TIMER Disable 20 60 1000 Disable 20 60 1000 Disable 20 60 1000 Disable 20 60 1000 1. GVRP Mode : disabled 2. View/Change Interface : 3. Main Menu Figure 25. GVRP Information Screen 4.7 Port Information The Port Information screen shows the current conditions for all ports in the 9161 with options to view parameters and statistics for specific ports. See Figure 26 and Table 8.
1. 2. 3. 4. 5. 6. 7. 8. 9. 10G 1 INFORMATION Model Number : 9500-330 Model Description : 10/100/1000 UTP Interface Serial Number : 20031122137 Model Revision : A1 Link Status : Link Up LLF Status : No LLF condition for this port Remote Fault Status : None Physical Status : 100 Full Admin Mode : enable Flow Control : disable Link Trap : enable Physical Mode : AutoNeg LACP Mode : enable Network Led : off LLF Partner : disable LLF Direction : disable Remote Fault : disable Main Menu Figure 27.
1. 2. 3. 4. REPORTS Description Traps Log Fdb Log Main Menu Figure 29. Reports Menu Table 9. Reports Menu Option Definitions Parameter Description 1. Description View the device type and firmware information; see Figure 30 2. Traps Log View a list of trap occurrences; see Figure 31 3. Fdb Log View a list of MAC addresses that this STP node has learned; see Figure 32 4.
FDB LOG Count VlanId 156 157 158 159 160 161 162 163 00 00 00 00 00 00 00 00 01 01 01 01 01 01 01 01 00 00 08 08 08 08 44 52 MAC D0 E0 00 00 00 00 45 54 B7 B0 09 11 20 4E 49 4C 83 8E FD 10 F0 37 00 83 45 5F 8B 2D E4 65 0E 88 CB 31 F9 99 A5 3C 0C 4F Port Status 1 1 1 1 1 1 1 1 learned learned learned learned learned learned learned learned Of: 163 Figure 32. FDB Log 4.
LATENCY/JITTER TEST Test IP Address Test Duration Round Trip Packets Dropped Packets 172.16.150.1 07:00 720 0 Minimum Latency (ms) Average Latency (ms) Maximum Latency (ms) 7.087695 8.004562 11.85647 1) 2) 3) 4) 5) 6) Minimum Jitter (ms) Average Jitter (ms) Maximum Jitter (ms) Test IP Address Duration (second) Size of packet Start Test Stop Test Main Menu : : : 0.001435 0.076897 1.289573 172.16.2.72 55 32 Figure 34. Latency/Jitter Test Screen Table 10.
4.10 Utilities Use the Utilities screen to set the time and date, restore defaults, reset the system, or start using new firmware. See Figure 36 and Table 11. To access the Utilities screen, follow this step: 1. From the Main Menu, type 6, "Utilities," and press . The Utilities menu appears. 2. From the Utilities menu, type the number for an item and press . 3. To return to the Main Menu, type 5.
4-22 9161 Network Interface Device
Chapter 5 Maintenance and Troubleshooting 5.1 General Maintenance Well-maintained components and clearly identified cables help assure optimum system operation. Damaged fiber cables and dirty connectors are a common source of signal loss or attenuation. Single mode and multimode fiber optics are especially sensitive to contamination. Inspect, clean, and test all components to maintain optimum performance. Note: • • • To avoid damage and signal loss, do not over-tighten or force-fit optical connectors.
5.3.1 Measure Transmitter Output Power To measure the output power, follow these steps: 1. Clean the connectors on the fiber optic test cable, then plug it in to the Tx connector on the 9161. 2. Warm up each component for at least 30 minutes. 3. Set the optical power meter to the proper wavelength. 4. Wait two or three minutes for the power reading to stabilize, and then read the output power. 5.
5.3.3 Measure Fiber Link Attenuation Determine and record link attenuation before starting normal link traffic. The attenuation factor identifies potential problems with links that are on the threshold of receiver limitations. Measure optical fiber links at the shortest wavelength of operation to determine the limiting factor in the loss budget. Each device that transmits to an 9161 has a loss budget that is specified by the manufacturer and recorded on a data sheet provided with the equipment.
5.4.2 New Installation On new installations, make sure that all steps in Chapter 2 are complete, then follow these steps: 1. Check that the STA LED is green. 2. Check that the fiber type is single mode. 3. Make these checks: • • • • • All fiber cabling is of the same type; do not mix multimode and single mode cables. The fiber optic cable is within the specifications and loss budget of the optic interface module.
Chapter 6 Specifications See also the specifications for the chassis or standalone enclosure. 6.1 9161 Specifications Standards: IEEE 802.3 Dimensions: 1.72" H x 13.375" W x 17.25" D (44 x 340 x 438 mm) Weight: 0.3 lb. (0.136 Kg) Operating Temperature: 0° to 50° C Operating Humidity: Up to 90% (non-condensing) Power Consumption: 5 VDC 800 mA Maximum Optical Connectors: ST or SC Regulatory Compliance • • • • • • • • ETL, cETL & LVD (UL 60950 CAN/CSA C22.2 No.
6-2 9161 Network Interface Device
Appendix A Warranty Limited Lifetime Warranty Effective for Products Shipped February 1, 2003 and After, Canoga Perkins warrants that, at the time of sale, and, for its lifetime, with certain exceptions noted below, every Canoga Perkins' labeled product purchased will be free from defects in material and workmanship for its lifetime, if properly installed and used in conformity to Canoga Perkins' published specifications. This warranty covers the original user only and is not transferable.
Limitations Canoga Perkins may at its sole discretion modify its Limited Warranty at any time and from time to time. Other than those expressly stated herein, THERE ARE NO OTHER WARRANTIES OF ANY KIND, EXPRESSED OR IMPLIED, AND SPECIFICALLY EXCLUDED BUT NOT BY WAY OF LIMITATION, ARE THE IMPLIED WARRANTIES FOR FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY.
Appendix B Acronym and Abbreviation List FPGA Field Programmable Gate Array GARP General Attributes Registration Protocol for registering a client station in a multicast domain GVRP GARP VLAN Registration Protocol for registering a client station in a VLAN Lag Link Aggregation Protocol LLF Link Loss Forwarding LNK Link MMF Multimode Fiber MST Multiple Spanning Tree PHY Physical Layer RMTF Remote Fault Rx Receive signal SBMC Side-Band Management Channel SM Single Mode SMF Single Mo
CANOGA PERKINS CORPORATION 20600 Prairie Street Chatsworth, California 91311-6008 USA Phone: (818) 718-6300 FAX: (818) 718-6312 Web Site: www.canoga.com Email: fiber@canoga.