User Manual

Menu Description
96
HDBaseT
Enable or disable HDBaseT input. For details on HDBaseT connections, see “Connection
Procedure” (P44, P45).
Option Function
Off Disable HDBaseT.
On Enable HDBaseT.
Image signal
quality
The HDBaseT input signal value received is indicated by a white line.
High
Indicated by the green portion. This is the recommended
level.
Middle
Indicated by the yellow portion. The signal is fluctuating.
Check the cable.
Low
Indicated by the red portion. The signal cannot be used. Fix
the cable connection or replace the cable.
Serial communication
Select the port used for serial communication. Otherwise, you can refer to this setting to
check setting values for the selected port.
Option Function
Service port Use the RS-232C port (service port).
HDBaseT Use the HDBaseT serial port.
Detail
Display setting values for the selected serial communication.
Stop bit Length of mark representing the end of data bits.
Baud rate Modulation rate, in bits per second.
Data bits Number of bits of data.
Parity Number of parity bits.
Do not coil or bundle cables.
Only [Service port] is available when [HDBaseT] (P96) is set to [Off].