Owner's Manual

Table Of Contents
Custom Picture Settings
126
[Knee]*
[Activate] [On], [Off]
Set this setting to [On] to enable the adjustment of the knee point with the following settings. When
[Gamma] is set to [Wide DR], [PQ], [HLG] or [Canon Log 3], the [Knee] settings are not available.
[Automatic] [On], [Off]
Set this setting to [On] to enable the automatic adjustment of the [Knee] settings.
[Slope] –35 to 50 (±0)
[Point] 50 to 109 (95)
[Saturation] –10 to 10 (±0)
These settings control the upper part of the gamma curve (highlights of the image). By compressing
the highlights, you can prevent parts of the image from being overexposed.
[Slope]: Determines the slope of the gamma curve above the knee point.
[Point]: Sets the knee point of the gamma curve.
[Saturation]: Adjusts the color saturation in the highlights.
[Sharpness]*
[Level] –10 to 50 (±0)
Sets the sharpness level of the video output signal and the recorded signal.
[Detail Frequency] –8 to 8 (±0)
Sets the center frequency of horizontal sharpness. Setting higher values increases the frequency,
which, in turn, increases the sharpness.
[Coring Level] –30 to 50 (±0)
Sets the level of correction of artifacts caused by high sharpness levels (coring). Higher values
prevent sharpness from being applied to minute details, resulting in less noise.
[HV Detail Bal.] –8 to 8 (±0)
Adjusts the ratio between horizontal and vertical detail. Higher values emphasize vertical detail while
lower values emphasize horizontal detail.
[Limit] –50 to 50 (±0)
Restricts how much sharpness is applied.
Menu items Setting options and additional information
Input
OutputOutput
Input
[Slope]
[Point]