Specifications

Command Descriptions
TDS3000, TDS3000B, and TDS3000C Series Programmer Manual
2- 231
MEASUREMENT:REFLEVEL:PERCENT:LOW?
might return :MEASUREMENT:REFLEVEL:PERCENT:LOW 1.5E1, meaning that the
low reference level is 15% of HIGH.
MEASUrement:REFLevel:PERCent:MID
Sets or returns the percent, where 100% is equal to HIGH, that is used to
calculate the mid reference level when MEASUrement:REFLevel:METHod is
set to PERCent. This command is equivalent to setting the relevant Reference
Levels in the MEASURE menu.
Measurement
MEASUrement:REFLevel:PERCent:MID <NR3>
MEASUrement:REFLevel:PERCent:MID?
<NR3> ranges from 0 to 100 percent, and is the mid reference level.
The default is 50%.
MEASUREMENT:REFLEVEL:PERCENT:MID 60
specifies that the mid reference level is set to 60% of HIGH.
MEASUrement:REFLevel:PERCent:MID2
Sets or returns the percent, where 100% is equal to HIGH, that is used to
calculate the mid2 reference level for the second waveform specified when
taking a delay measurement. This command is equivalent to setting the relevant
Reference Levels in the MEASURE menu.
Measurement
MEASUrement:REFLevel:PERCent:MID2 <NR3>
MEASUrement:REFLevel:PERCent:MID2?
<NR3> ranges from 0 to 100 percent, and is the mid reference level. The
default is 50%.
Examples
Group
Syntax
Arguments
Examples
Group
Syntax
Arguments