Service manual

R72
3-5-2 Optical Unit Adjustment
Tools Used
Personal Computer Compact Power Adapter CA-560
INTERFACE CABLE IFC-200PCU Adjustment Software
Auto Focus Chart Tripod
1
2
3
Click the “Optical Unit”button.
When the message on the right appears,
go to 3.
q Place the Auto Focus Chart 47cm away from
the finder of camera front.
* Place the Auto Focus Chart on a plain color
wall or equivalent.
* Adjust the light so that the brightness of
the chart will be about EV8.5.
w Fine-adjustment the position of the camera
so that the center of the Auto Focus Chart is
aligned with the center of the LCD.
e Click the “ADJUST” button.
Personal
Computer
Power
Source
47cm
AUTO FOCUS CHART
CAMERA
BODY
Tripod