Service manual

Chapter 3
3-24
F-3-149
When attaching the top cover, be sure to match its 2 positioners [1] and the
2 cut-offs [2] of the face-down sub cover, while making sure that the paper
retainer [3] is not blocking the feed path.
F-3-150
F-3-151
When attaching the top cover, be sure to fit the link lever [2] while keeping
the drive release lever [1] in up position (i.e., with drive disengaged).
F-3-152
If you are fitting the drum cartridge in the machine with the top cover re-
moved, be sure to do so with the drive release lever [1] fully in up position
(i.e., with drive disengaged).
If the drive release lever is in low position (i.e., with drive engaged), it forces
out the coupling [2], causing the coupling to interface with the drum car-
tridge and to suffer damage.
F-3-153
3.2.12.8 Removing the Right Frame
0011-6589
1) Remove the 5 screws [1], and detach the right frame [2].
F-3-154
3.2.12.9 Removing the Shield Plate
0011-6611
1) Free the flat cable [1] from the connector.
2) Remove the 6 screws [2], and detach the shielding plate [3].
[4]
[1]
[1]
[2]
[3]
[1]
[2]
OK NG
Enlarged View of the Paper Retainer
[3]
[3]
[1]
[2]
[1]
[2]
[1]
[1]
[2]