Service manual

Chapter 3
3-97
F-3-635
3.5.5.8 Removing the Right Frame
0011-6598
1) Remove the 5 screws [1], and detach the right frame [2].
F-3-636
3.5.5.9 Removing the Shield Plate
0011-6619
1) Free the flat cable [1] from the connector.
2) Remove the 6 screws [2], and detach the shielding plate [3].
F-3-637
3.5.5.10 Removing the Rotary Drive Assembly
0007-8869
1) Disconnect the 4 connectors [1], and remove the 2 screws [2].
F-3-638
2) Disconnect the connector [1], and remove the 3 screws [2]; then, detach
the rotary drive assembly [3].
F-3-639
Be sure to tighten the self-tapping screw used to secure the rotary drive as-
sembly only at the end of the work.
3.5.5.11 Removing the Developing Rotary Motor
0007-8870
1) Remove the 2 screws [1], and detach the toner cartridge motor [2] from
the rotary drive assembly.
F-3-640
3.5.6 Developing Rotary Stopper Solenoid
3.5.6.1 Removing the Rear Cover
0007-8558
1) Disconnect the cable [1] of the power supply assembly.