Service manual

Chapter 3
3-102
F-3-666
3.5.6.13 Removing the Developing Rotary Stopper
Solenoid
0007-8875
1) Remove the 3 screws [1], and detach the motor base [2] from the rotary
drive assembly.
F-3-667
2) Remove the screw [1], and detach the developing rotary stopper solenoid
[2] from the rotary drive assembly.
F-3-668
3.5.7 Density Detection PCB
3.5.7.1 Removing the Rear Cover
0007-8551
1) Disconnect the cable [1] of the power supply assembly.
2) Open the face-up cover [2], and remove the 4 screws [3] of the rear cover.
F-3-669
3) Open the reader assembly [4], and lift to free the 2 claws [5].
F-3-670
4) Close the reader assembly; then, detach the rear cover[1].
F-3-671
3.5.7.2 Removing the Reader Assembly
0007-8569
1) Open the reader assembly, and remove the left and right E-rings [1]; then,
pull out the pin [2].
F-3-672
When closing the reader assembly, be sure to push in the arm [1] first.
[1]
[2]
[1]
[1]
[2]
[1]
[2]
[2]
[3]
[1]
[3]
[4]
[5]
[2]
[3]
[1]
[3]
[2]
[1]
[2]
[1]