Service manual

Chapter 3
3-105
F-3-685
F-3-686
When attaching the top cover, be sure to fit the link lever [2] while keeping
the drive release lever [1] in up position (i.e., with drive disengaged).
F-3-687
If you are fitting the drum cartridge in the machine with the top cover re-
moved, be sure to do so with the drive release lever [1] fully in up position
(i.e., with drive disengaged).
If the drive release lever is in low position (i.e., with drive engaged), it forces
out the coupling [2], causing the coupling to interface with the drum car-
tridge and to suffer damage.
F-3-688
3.5.7.8 Removing the Inside Cover
0007-8856
1) Remove the 2 claws [1], and detach the inside cover [2].
F-3-689
3.5.7.9 Removing the Dust-Blocking Cover
0007-8858
1) Remove the claw [1], and detach the dust-blocking cover [2].
F-3-690
3.5.7.10 Removing the Density Detection PCB
0007-8859
1) Remove the 2 screws [1], and disconnect the connector [2]; then, detach
the density detection PCB [3].
[1]
[2]
OK NG
Enlarged View of the Paper Retainer
[3]
[3]
[1]
[2]
[1]
[2]
[1]
[2]
[1]
[2]