Service manual

Chapter 3
3-123
F-3-799
F-3-800
When attaching the top cover, be sure to fit the link lever [2] while keeping
the drive release lever [1] in up position (i.e., with drive disengaged).
F-3-801
If you are fitting the drum cartridge in the machine with the top cover re-
moved, be sure to do so with the drive release lever [1] fully in up position
(i.e., with drive disengaged).
If the drive release lever is in low position (i.e., with drive engaged), it forces
out the coupling [2], causing the coupling to interface with the drum car-
tridge and to suffer damage.
F-3-802
3.5.12.8 Removing the Right Frame
0011-6602
1) Remove the 5 screws [1], and detach the right frame [2].
F-3-803
3.5.12.9 Removing the Shield Plate
0011-6621
1) Free the flat cable [1] from the connector.
2) Remove the 6 screws [2], and detach the shielding plate [3].
F-3-804
3.5.12.10 Removing the Rotary Drive Assembly
0007-8865
1) Disconnect the 4 connectors [1], and remove the 2 screws [2].
[1]
[2]
OK NG
Enlarged View of the Paper Retainer
[3]
[3]
[1]
[2]
[1]
[2]
[1]
[1]
[2]
[2]
[2]
[3]
[1]