F-3-1023
4) Pressing the boss [1] inward, rotate the delivery idle gear shaft holder [2]
in the direction of the arrow and remove the holder together with the
delivery idle gear shaft [3].
F-3-1024
5) Remove the 4 screws [1]; then, remove the 2 claws [2] and the boss [3] to
detach the fixing upper cover [4].
F-3-1025
Make sure that the 2 springs are fitted onto the bosses on the fixing upper
cover when reassembling the cover. See the figure for the correct positions
of the boss and springs (shown on the left).
F-3-1026
6) Remove the upper separation guide [1].
7) Remove the 2 releasing levers [2].
8) Slide the pressure plate [4] in upward direction, and remove the 2 bosses
[3].
9) Remove the pressure plate [4] from the fixing assembly.
F-3-1027
10) Disconnect the connector [1], and free the cable [2] from the clamp [3].
11) Remove the screw [4].
F-3-1028
12) Remove the cable [1] from the guide [2].
13) Remove the 2 claws [4], and disconnect the connector [3].
14) Free the cable from the edge saddle [5].
F-3-1029
15) Remove the 1 screw [1] and slide the fixing separation guide [2] out to
the left.