Service manual

Chapter 3
3-165
F-3-1068
3.7.5.18 Removing the Lower Case Assembly
0007-8904
1) Remove the screw [1], and disconnect the 5 connectors [2].
F-3-1069
2) Remove the screw [1] from the left side of the machine.
F-3-1070
3) With care, shift down the machine to the left; then, remove the 8 screws
[2] from the bottom, and detach the lower case assembly [3].
F-3-1071
When you shift down the machine, be sure to take care to avoid injury by the
edge of the side plate. Also, be sure to hold it by its grip segment.
Be sure to place a cushioning material (g., towel) on the work table to protect
the protrusions of the machine from damage.
Moreover, be sure to tape the opening of the laser scanner assembly to pre-
vent intrusion of toner in the optical path of the assembly before shifting
down the machine.
If you must detach the lower case assembly, base user to hold it by its bottom
so as to avoid injury by the edge of its side plate.
3.7.5.19 Removing the Fixing Front Paper Sensor
0007-8906
1) Bend over the plastic sheet [1].
2) Remove the screw [2], and detach the fixing front paper sensor assembly
[3].
F-3-1072
3) Remove the 2 claws [1], and detach the fixing front paper sensor [2]; then,
disconnect heat connector [3].
F-3-1073
3.7.6 Fixing Motor
3.7.6.1 Removing the Rear Cover
0007-8554
1) Disconnect the cable [1] of the power supply assembly.
2) Open the face-up cover [2], and remove the 4 screws [3] of the rear cover.
[1] [1]
[1][1]
[2]
[3]
[1]
[2]
[1]
[2]
[3]
[2]
[2]
[2]
[1]
[2][3]
[1]
[2]
[3]