9) Remove the pully clip, and detach the scanner cable (both front and rear).
3. Assembling the Mirror Position Tool
1) Remove the screw found in position B.
Figure 3-407
2) Fit the screw removed in step 1) in position A, and tighten it slightly.
3) Extend the arm accommodated by the main frame unit it butts against the stopper as
in Figure 3-408.
4) Tighten the screw.