CHAPTER 6 FIXING SYSTEM
6-15 P
4) Free the claw [2] of the inlet lower
guide [1], and slide it to the rear to re-
move.
Take care not to damage the fix-
ing roller. When mounting,
avoid pushing it against the fix-
ing roller.
F06-401-10
5) Lift the rear of the fixing roller assem-
bly [1], and slide it to the rear to re-
move.
F06-401-11
6) Detach the two roller bushings [2] from
the fixing roller [1].
7) Remove the conducting rubber [3].
F06-401-12
[1]
[2]
[1]
[3]
[1]
[2]
[2]