Product specifications

DC10 E, DC20 E
DISASSEMBLING
43
1-24 Disassembly of CVF Unit - 1
(1) Detach the CVF Dust Cover, and remove one screw (i × 1), and then detach the CVF L Cover and CVF Eyecup.
(2) Peel of the UL Tape, and remove one screw (i × 1), and then detach the CVF GND Plate, the CVF Diop Plate, the CVF Diop Knob,
the CVF Diop Rubber, and the CVF Lens Holder.
(3) Disengage two claws A, and detach the CVF Lens.
Fig. 40
i
4mm
Metal
M1.7
(self tap)
(1)
(1)
(2)
(2)
(2)
(2)
(1)
(3)
Claws A
CVF Eyecup
CVF Lens
CVF L Cover
CVF Dust Cover
CVF Dust Cover
CVF Diop Knob
CVF Diop Rubber
CVF Diop Plate
CVF GND Plate
CVF Lens Holder
UL Tape
(7 × 15mm)
Tweezers
(1) - i
(2) - i