Product specifications

DC10 E, DC20 E
SERVICE MODE / ADJUSTMENT
27
5-5 CCD Section (2) (DC20 E only)
5-5-1 Internal Camera Temperature Check (3)
(1) Adjustment Conditions
Movie/Still : Movie
Shotting mode : Program AE
AF : Closest focus
ZOOM : Telephoto-end
Electronic zoom : OFF
Image stabilizer : OFF
Preparation)
(1) For adjustment, provide the same tool and connections as in 5-2 “CCD Section (1)”. (The LED light source should be removed
until item 5-5-2.)
Procedure)
(1) Press the SLOW KEY, check the internal temperature sensor in the camera.
(Perform this step about 20 to 50 minutes after power-on.)
(2) Using the internal camera temperature data, calculate a value of the current internal temperature, and record the calculated value.
Temperature 20 to 50 minutes after power-on T3 = ____________
(3) Calculate an increase in the internal camera temperature [°C], and check that it is in the range of 15[°C] to 20[°C].
Increase in internal camera temperature [°C] = (T2 - T1) + T3
(4) If an increase in the internal camera temperature exceeds 20°C, turn power off and then wait until a temperature level of less than
20°C is reached. Then, proceed to items 5-5-2 and subsequent.
If an increase in the internal camera temperature is less than 15°C, wait until a temperature level exceeding 15°C is reached.
Then, proceed to items 5-5-2 and subsequent.
<Reference>
Note)
The internal camera temperature check procedures are complete at this step. After checking the internal camera temperature
difference, be sure to reset DATA to 00.
STEP PROCEDURE Microcomputer operation
TEMPERATURE CHECK CS Function MD ADDR DT
1 1) Make the setting shown at right. 0 02 ST 00D0 00 Release of internal camera temperature sensor
2) Perform storing.
↑↑
RD
↑↑
check indication.
(press the PAUSE button.) Release is completed.
2 Press SLOW KEY for transition to the normal mode. Indication of internal camera temperature
MONITOR
Fig. 20
Internal camera temperature difference