Product specifications

DC10 E, DC20 E
SERVICE MODE / ADJUSTMENT
38
5-8 CVF Adjustment
For this camcorder, CVF adjustment is optional. However, if malfunction is found in CVF image, picture quality or color after replace-
ment of a CVF-related part, be sure to carry out the following adjustment.
Note)
(1) The adjustments from 5-8-3 through 5-8-5 must be carried out in sequence.
Remember that Satisfactory performance will not be attained unless all adjustments are performed.
Preparation)
(1) Carry out CVF adjustment in the camera mode in the product condition.
5-8-1 Forced CVF ON, Adjustment Image (B/W) Setting
Procedure)
(1) Referring to the table shown below, make the setting.
5-8-2 CVF Frequency Adjustment
M. EQ. Frequency counter
TP. Extension connector - pin 4 (EVF HD)
SPEC. 15.734 ± 0.1kHz
Procedure)
(1) Carry out adjustment according to the table shown below.
Note) When the following adjustment is in progress (MD: ST), the LCD and CVF images are not synchronized, but it
is not malfunction.
CS Function MD ADDR DT
Forced CVF ON 1) Make the setting shown at right
.
0 00 ST 0004 02 Start of setting
2) Perform storing.
↑↑
RD
↑↑
Completion of setting
(press the PAUSE button.)
Black and white image 1) Make the setting shown at right
.
208ST330F--
2) Perform storing.
↑↑
RD
↑↑
Completion of setting
(press the PAUSE button.)
STEP PROCEDURE
MONITOR
Adjustment points and range
CS Function MD ADDR DT
CVF Frequency 1) Make the setting shown at right
.
021ST0003
"ADJ"
Start of setting
Adjustment 2) Perform storing.
↑↑
RD
ADJ Completion of setting
(press the PAUSE button.)
STEP PROCEDURE
MONITOR
Adjustment points and range