17. Moisture Resistant Treatment
Apply moisture-proofing (Tuffy TF-1156) at the points indicated by hatching.
1. On the body at the SW 18 mounting
position.
2. On the body at the SW 12 mounting
position.
3. SW 18 assembly
(To the contact
base)
4. Timer lamp contact assy.
Cover completely
5. Main flex./ SV Connector
6. Pentaprism Contacts (X contact)
7. Top Cover (Right) Approx. 30mm
8. MD contact (back side)