Operation Manual

5-101
FAX-L1000 Chapter 5: Appendix
Duplexing unit(J702) ,/ Duplex feed motor
J701 Motor Signal name Description
1 / 1 FMT A Duplex feed motor drive signal
2 / 2 nFMT A Duplex feed motor drive signal
3 / 3 FMT B Duplex feed motor drive signal
4 / 4 nFMT B Duplex feed motor drive signal
Duplexing unit(J703) ,/ Duplex unit solenoid
J703 Soleniod Signal name Description
1 / 1 +24V Duplexing unit solenoid drive voltage
2 / 2 DUP SOL Duplexing unit solenoid drive signal
Duplexing unit(J704) ,/ ECNT board(J71)
J704 J71 Signal name Description
1 / 6 +24V Duplexing unit drive voltage
2 , 5 nSEL0 Duplexing unit select signal
3 . 4 DGND Ground
4 , 3 SOUT Serial input data
5 / 2 SIN Serial output data
6 / 1 SCLK Serial clock signal
Duplexing unit(J705) ,/ Reversed paper sensor
J705 Sensor Signal name Description
..4 N.C Not connected
1 / 3 INV DR Reversed paper sensor drive
2 . 2 DGND Ground
3 , 1 INV SNS Reversed paper detection signal
Duplexing unit(J705) ,/ Face-up sensor
J705 Sensor Signal name Description
4 / 3 FU DR Face-up sensor drive
5 . 2 DGND Ground
6 , 1 FU SNS Face-up detection signal
Duplexing unit(J706) ,/ Duplexing unit pick-up sensor
J706 Sensor Signal name Description
1 .. N.C Not connected
2 / 3 PICK DR Duplex pick-up drive
3 . 2 DGND Ground