Operation Manual

5-183
FAX-L1000 Chapter 5: Appendix
##1061 [TX/RX] Called party is closed or does not support the service
Cause: Indicated above
Solutions: (1) Designated number/Re-check the contract, and re-transmit.
(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in
#4C ISDN BASIC, [G4/G3 Fallback]
and
[Speech Fallback]
.
(4) Take countermeasures as outlined in
D-channel connection
error
in
this Chapter, 3.6.6 Maintenance and service, c)
Communication problems.
(5) Make an inquiry to the maker of the Switching equipment.
##1062 [TX/RX] a) Active rejection of connection through the called party
b) Disconnection from network
Cause a): Indicated above
Solutions a): (1) Re-check the telephone number, then re-transmit.
(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in
#4C ISDN BASIC, [G4/G3 Fallback]
and
[Speech Fallback]
.
(4) Take countermeasures as outlined in
D-channel connection
error
in
this Chapter, 3.6.6 Maintenance and service, c)
Communication problems.
(5) Make an inquiry to the maker of the Switching equipment.
Cause b): Indicated above
Solutions b): (1) Re-check the telephone number, then re-establish communication.
(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in
#4C ISDN BASIC, [G4/G3 Fallback]
and
[Speech Fallback]
.
(4) Take countermeasures as outlined in
D-channel connection
error
in
this Chapter, 3.6.6 Maintenance and service, c)
Communication problems.
(5) Make an inquiry to the maker of the Switching equipment.
##1063 [TX/RX] Service or option not available, unspecified.
Cause: Indicated above
Solutions: (1) Re-check the designated service contract, and re-establish
communication.
(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in
#4C ISDN BASIC, [G4/G3 Fallback]
and
[Speech Fallback]
.
(4) Take countermeasures as outlined in
D-channel connection
error
in
this Chapter, 3.6.6 Maintenance and service, c)
Communication problems.
(5) Make an inquiry to the maker of the Switching equipment.