Operation Manual

5-187
FAX-L1000 Chapter 5: Appendix
##1089 [TX/RX] Line busy
Cause: Indicated above
Solutions: (1) Re-transmit.
(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in
#4C ISDN BASIC, [G4/G3 Fallback]
and
[Speech Fallback]
.
(4) Take countermeasures as outlined in
D-channel connection
error
in
this Chapter, 3.6.6 Maintenance and service, c)
Communication problems.
(5) Make an inquiry to the maker of the Switching equipment.
##1090 [TX/RX] Release from the other party number or from a distant exchange
Cause: Indicated above
Solutions: (1) Re-establish communication.
(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in
#4C ISDN BASIC, [G4/G3 Fallback]
and
[Speech Fallback]
.
(4) Take countermeasures as outlined in
D-channel connection
error
in
this Chapter, 3.6.6 Maintenance and service, c)
Communication problems.
(5) Make an inquiry to the maker of the Switching equipment.
##1091 [TX/RX] Invalid transit network selection
Cause: Indicated above
Solutions: (1) Re-check the designated relay network, and re-transmit.
(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in
#4C ISDN BASIC, [G4/G3 Fallback]
and
[Speech Fallback]
.
(4) Take countermeasures as outlined in
D-channel connection
error
in
this Chapter, 3.6.6 Maintenance and service, c)
Communication problems.
(5) Make an inquiry to the maker of the Switching equipment.
##1092 [TX/RX] Disconnection from network
Cause: Indicated above
Solutions: (1) Re-check the phone number and try the call again.
(2) Output a communications analysis list, and analyze it.
(3) Make sure the 4 digits of the applicable error code are registered in
#4C ISDN BASIC, [G4/G3 Fallback]
and
[Speech Fallback]
.
(4) Take countermeasures as outlined in
D-channel connection
error
in
this Chapter, 3.6.6 Maintenance and service, c)
Communication problems.
(5) Make an inquiry to the maker of the Switching equipment.