Operation Manual

5-207
FAX-L1000 Chapter 5: Appendix
c) Signal description
Ethernet board(J1) ,/ Network
J1 Network Signal name Description
1 / Network TX+ Send Data Line(+)
2 / Network TX- Send Data Line(-)
3 , Network RX+ Receive Data Line(+)
4 . Network N.C. Not used
5 . Network N.C. Not used
6 , Network RX- Receive Data Line(-)
7 . Network N.C. Not used
8 . Network N.C. Not used
Ethernet board(J3) ,/ Adapter board connector(J2)
J3 J2 Signal name Description
A1 . A1 +5V Logic drive voltage
A2 / A2 nINTR Interrupt request
A3 , A3 nRESET Reset
A4 , A4 nIOWR I/O Write
A5 , A5 nIOCS I/O Chip select
A6 . A6 (Reserved)
A7 . A7 GND Ground
A8 . A8 D00 Data bit 0
A9 . A9 D02 Data bit 2
A10 . A10 D04 Data bit 4
A11 . A11 D06 Data bit 6
A12 . A12 D08 Data bit 8
A13 . A13 D10 Data bit 10
A14 . A14 D12 Data bit 10
A15 . A15 D14 Data bit 10
A16 . A16 GND Ground
A17 , A17 A02 Address bit2
A18 , A18 A04 Address bit4
A19 , A19 A06 Address bit6
A20 , A20 A08 Address bit8
A21 , A21 A10 Address bit10
A22 , A22 A12 Address bit12
A23 , A23 A14 Address bit14
A24 , A24 A16 Address bit16
A25 , A25 +5V Logic drive voltage
B1 . B1 GND Ground
B2 / B2 nWAIT Wait
B3 , B3 nWnR Write/Read
B4 , B4 nIORD I/O Read enable
B5 , B5 A23 Address bit23