(Target Position Data) XDATYDAT
The data length of the target position data by the high-speed serial communication can be
changed by two following parameters.
The target position data length can be changed in 16bit – 20bit.
Parameter ID DATA
67
1616bit Data
1717bit Data
1818bit Data
1919bit Data
2020bit Data
The least significant bit position of the target position data of high-speed serial communication
20bit data can be set by following parameter.
The right shifts this number of bit make the target position data.
Parameter ID DATA
68
00bit position
11bit position
22bit position
33bit position
44bit position
An example of the setting as follows.
Parameter ID = 67 16
Parameter ID = 68 1
Parameter ID = 67 18
Parameter ID = 68 2
(Bit) 1234567891011121314151617181920
XDAT C2 C1 C0 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 P
YDAT C2 C1 C0 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 P
16bit
Data
(Bit) 1234567891011121314151617181920
XDAT D17 D16 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 C1 C0
YDAT D17 D16 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 C1 C0
18bit
Data