Service manual

Chapter 10
 
10-50
F-10-199
10.4.17.3 Adjust the left/right
registration 0007-0403
Using the ADF, make a copy of the sheet in Direct,
and check to make sure the left/right registration is 10
+/- 1 mm.
F-10-200
1) Pick the tab [1], and detach the white plate [2].
F-10-201
2) Loosen the screw [3], and move the slide guide to
the front/rear with reference to the index graduated
at 1-mm intervals until the registration is as
indicated.
F-10-202
MEMO:
A shift of the slide guide up by 1 mm will increase the
registration on the right (top of paper) by 1 mm.
Do not remove the screw [3]; otherwise, you must
work as instructed for mounting of the slide guide.
10.4.18 Delivery Stacking Tray
10.4.18.1 Removing the Left
Cover 0007-0244
1) Remove the screw [1], and detach the left cover [2].
[2]
[1]
Copy of the test sheet
(feeding direction)
10±1mm
[1]
[2]
[3]