Service manual

Chapter 14
14-7
14.2.1.3 How to Record the Protocol 0006-4428
If you are instructed to "record the communication procedure sound on a DAT or MD, and ask the Technical Center
for analysis", refer to the following diagram for a generally used method of connection:
F-14-1
14.2.2 User Error Code
14.2.2.1 Causes and Remedies for User Error Codes 0006-4431
The causes and remedies for individual user error codes are as follows:
T-14-2
#001 [TX] Document has jammed
Cause: The original is trapped in the feeder
Remedy: Remove the document, and try again.
Cause: The original is not of a standard size or thickness.
Remedy: (1) Make a copy on A4/LTR paper in book mode, and transmit the output.
(2) If the original is too thin or too small, transmit it in book mode.
Cause: An internal mechanism is faulty.
Remedy: (1) Check the connection of the DS sensor (original sensor), DES sensor
(registration sensor), and image processor PCB.
(2) Check the following to see if they operate normally: DS sensor (original
sensor), DES senor (registration sensor).
Telephone line
G3 Recording Adaptor
DAT recorder
or
MD recorder
Use Standard (SP) mode for recording.
Set the recording level so that the sound of communication
can clearly be heard with as little noise as possible when replayed.
LINE IN
FAX
TELLINE
LINE
FAX