Remedy: Transmit once again.
##287 [TX] DCN has been received after transmitting MPS
Cause: The Stop button was pressed during a communication.
Remedy: Transmit once again.
##288 [TX] After transmitting EOP, a signal other than PIN, PIP, MCF, RTP, or
RTN was received
Cause: The procedure signal has a fault.
Remedy: Record the protocol on a DAT or MD, and have it analyzed by the local
Canon office and/or Technical Center.
##289 [TX] After transmitting EOM, a signal other than PIN, PIP, MCF, RTP, or
RTN was received
Cause: The procedure signal has a fault.
Remedy: Record the protocol on a DAT or MD, and have it analyzed by the local
Canon office and/or Technical Center.
##290 [TX] After transmitting MPS, a signal other than PIN, PIP, MCF, RTP, or
RTN was received
Cause: The procedure signal has a fault.
Remedy: Record the protocol on a DAT or MD, and have it analyzed by the local
Canon office and/or Technical Center.
##670 [TX] In V.8 late start, the V.8 ability was detected in DIS from the other party
and, in response, CI was transmitted; however, the procedure failed to
advance, causing a T1 time-over condition.
Cause: CI was transmitted, but the other party failed to receive it correctly and
disconnect the line.
##286 [TX] DCN has been received after transmitting EOM