Service manual

Chapter 15
15-27
15.2.8 Setting the Original Reading Functions
0006-4073
T-15-20
7. CCD Settings
T-15-21
Item Description
1. Bit SW
Do not change the setting; otherwise, the read image
quality can be lost.
2. SLICE
3. GAMMA
4. Numeric
5. LUT 1 fno
6. LUT 2 adj
7. CCD partially hanged
8. MODEL not used
No. Item Unit of adjustment
0 to 18 Do not change.
-
19 shading position adjustment*1 (*2)
21 left/right edge read start position
adjustment
(book mode)
1 unit = approx. 0.03 mm
23 leading edge read start position
adjustment
(book mode)
1 unit = 0.1 mm
24 leading edge read start position
adjustment
(ADF mode)
1 unit = 0.1 mm
25 trailing edge read end position
adjustment
(ADF mode)
1 unit = 0.1 mm
26 to 33 Do not change. -
34 original feed speed adjustment
(ADF mode)
1 unit = approx. 0.5 mm