Service manual

Chapter 7
7-12
3) Disconnect the three connectors [3], and then remove the cassette pickup
assembly [4].
F-7-28
Install the cassette pickup assembly with the ground plate [1] outside the
side plate.
F-7-29
7.5.6.2 Removing the Cassette Pickup Solenoid
0011-0659
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Remove the harness [1] from the two wire saddles [2].
2) Remove the screw [3], and then remove the cassette pickup solenoid [4].
F-7-30
7.5.7 Manual Feed Tray sensor
7.5.7.1 Removing the Drum Unit
0011-0672
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Open the front cover [1].
2) Turn the developer pressure release lever [2] clockwise, and then open the
left door [3].
3) Draw out the drum unit [4].
F-7-31
To prevent exposure to light, cover the drum with several sheets of copy
paper and place it in a safe place.
Open the left door fully to prevent the damage to the drum unit
7.5.7.2 Removing the Transfer Registration Unit
0011-0673
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Remove the four screws [1], and then remove the transfer registration unit
[2].
F-7-32
7.5.7.3 Removing the Feed Guide
0011-0674
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Remove the two screws [1], and then remove the feed guide [2].
F-7-33
7.5.7.4 Removing the Multifeeder Paper Presence/
Absence Sensor
0011-0675
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Remove the two claws [1]. Remove the connector [2], and then remove
the multifeeder paper presence/absence sensor [3].
[1]
[2]
[3]
[1]
[3]
[4]
[
1]
[4][3][2][1]
[2]
[1]
[3]
[4]
[1]
[1]
[2]
[1]
[2]