Service manual

Chapter 14
14-3
06: 0 0: DIAL
1: SERVICEMAN [1]
2: SERVICEMAN [2]
3: OFF
line monitor setting
07: 10 0-15 transmission level setting
08: 0 0: 3429
1: 3200
2: 3000
3: 2800
4: 2743
5: 2400
V.34 baud rate
09: 0 0: 33.6kbs
1: 31.2kbs
2: 28.8kbs
3: 26.4kbs
4: 24.0kbs
5: 21.6kbs
6: 19.2kbs
7: 16.8kbs
8: 14.4kbs
9: 12.0kbs
10: 9.6kbs
11: 7.2kbs
12: 4.8kbs
13: 2.4kbs
V.34 transmission speed
10: 1 0: 50Hz
1: 25Hz
2: 17Hz
pseudo CI signal frequency setting
11: - 20: not used
#NUMERIC Param.
No. Initial setting Range of setting Function
001: not used
002: 10 (10%) (1 - 99) RTN signal transmission condition (1) setting
003: 15 (15lines) (2 - 9) RTN signal transmission condition (2) setting
004: 12 (12times) (1 - 99) RTN signal transmission condition (3) setting
005: 4 (4sec) (1 - 60) NCC pause time (pre-ID code) setting
006: 4 (4sec) (1 - 60) NCC pause time (post-ID code) setting
007: - 009: not used
010: 5500 (55sec) (0 - 9999) line connection identification time length
011: 3500 (35sec) (0 - 9999) T.30 T1 timer (for reception)
012: not used
013: 1300 (13sec) (500 - 3000) T30 EOL timer
014: not used
015: 120 (1200ms) (0 - 999) hooking detection time setting
016: 4 (4sec) (0 - 9) fax/tel switch-over function: between line acquisition and pseudo RBTtransmission
017: 100 (1000ms) (0 - 999) pseudo RBT signal pattern: ON time setting
018: 0 (0ms) (0 - 999) pseudo RBT signal pattern: OFF time (short) setting
019: 200 (2000ms) (0 - 999) pseudo RBT signal pattern: OFF time (long) setting
020: 100 (1000ms) (0 - 999) pseudo CI signal pattern: ON time setting
021: 0 (0ms) (0 - 999) pseudo CI signal pattern: OFF time (short) setting
022: 200 (2000ms) (0 - 999) pseudo CI signal pattern: OFF time (long) setting
023: 4 (0 - 7) fax/tel switch-over pseudo RBT transmission level
024: 20 (-20dBm) (0 - 20) fax/tel switch-over pseudo RBT transmission level
025: 60 (60sec) (0 - 999) pseudo RBT signal pattern: OFF time (long) setting
026: not used
027: 0 (0 - 20) V21 low-speed flag preamble detection time length
028: - 055: not used
056: 101 (0 - 999) count type select 1
057: 103 (0 - 999) count type select 2
058: 201 (0 - 999) count type select 3
059: 203 (0 - 999) count type select 4
060: 0 (0 - 999) count type select 5
061: 0 (0 - 999) count type select 6
062: - 080: not used
#SPECIAL Do not change.
#NCU Do not change.
#FAX Not used.
#MENU
No. Initial setting Range of
setting
Function