Service manual

Chapter 14
14-7
14.3 Setting of Bit Switch (SSSW)
14.3.1 Outline
14.3.1.1 Bit Switch Composition
0011-1732
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
The items registered and set by each of these switches comprise 8-bit switches. The figure below shows which numbers are assigned to which bits. Each bit has a
value of either 0 or 1.
F-14-2
Do not change service data identified as "not used"; they are set as initial settings.
14.3.2 SSSW-SW01
14.3.2.1 List of Functions
0011-1735
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
T-14-1
14.3.2.2 Detailed Discussions of Bit 0
0011-1736
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Selects whether or not service error codes are output.
When output is selected, service error codes is report.
14.3.3 SSSW-SW03
14.3.3.1 List of Functions
0011-1737
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
T-14-2
14.3.3.2 Detailed Discussions of Bit 7
0011-1738
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to enable/disable transmission of a 1080-Hz tonal signal before transmission of the CED signal.
Select 'transmit' if errors occur frequently because of an echo when reception is from overseas.
Memo:
Any of the following error code may be indicated because of an echo at time of reception
##0005, ##0101, ##0106, ##0107, ##0114, ##0200, ##0201, ##0790
14.3.4 SSSW-SW04
14.3.4.1 List of Functions
0011-1739
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Bit Function 1 0
0 service error code output not output
1 not used - -
2 not used - -
3 not used - -
4 not used - -
5 not used - -
6 not used - -
7 not used - -
Bit Function 1 0
0 not used - -
1 not used - -
2 not used - -
3 not used - -
4 not used - -
5 not used - -
6 not used - -
7 tonal signal before CED signal transmission transmit do not transmit
001
#SSSW
00000000
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0