Service manual

Chapter 14
14-11
14.3.10 SSSW-SW30
14.3.10.1 List of Functions
0011-3590
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
T-14-12
14.3.10.2 Detailed Discussions of Bit 5
0011-3592
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
When "Detect with the new method" is selected, tone is detected for 3.5 seconds before call origination in order to discriminate between dial tone and voice. If dial
tone is detected and the time since line seizure is 3.5 seconds or longer, call origination takes place immediately. If the time since line seizure is less than 3.5 seconds,
call origination takes place after waiting for 1 second. (If the time since line seizure reaches 3.5 seconds during the 1-second waiting period, call origination takes
place immediately. By default, "Detect with a new method" is assigned for this SW.
14.3.11 SSSW-SW33
14.3.11.1 List of Functions
0011-1761
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
T-14-13
14.3.11.2 Detailed Discussions of Bit 0
0011-1762
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to specify whether B4 paper (Print) should be counted as large-size paper.
If 'yes' is selected, B4 paper will be counted as large-size paper.
If 'no' is selected, on the other hand, B4 paper will be counted as small-size paper.
14.3.11.3 Detailed Discussions of Bit 1
0011-1763
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to specific whether to indicate the machine serial No. on the Counter Check screen, appearing when the Counter key is pressed.
If 'yes' is selected, the serial No. will be indicated.
If 'no' is selected, on the other hand, the serial No. will not be indicated.
14.3.11.4 Detailed Discussions of Bit 2
0011-1764
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to specify whether B4 paper (Scan) should be counted as large-size paper.
If 'yes' is selected, B4 paper will be counted as large-size paper.
If 'no' is selected, on the other hand, B4 paper will be counted as small-size paper.
14.3.11.5 Detailed Discussions of Bit 3
0011-1765
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Select whether to switch the counter display type in effect in Japan to the conventional or new type. Select "Yes" to display counters in the new type. Select "No"
to display counters in the conventional type.
14.3.12 SSSW-SW34
14.3.12.1 List of Functions
0011-1766
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
T-14-14
Bit Function 1 0
0 Not used - -
1 Not used - -
2 Not used - -
3 Not used - -
4 Not used - -
5 New dial tone detection method Detect with the new
method.
Detect with the
existing method.
6 Not used - -
7 Not used - -
Bit Function 1 0
0 count B4 (Print) as large size Yes No
1 indicate serial No. on counter check screen Yes No
2 count B4 (Scan) as large size Yes No
3 the counter display type change in Japan Yes No
4 not used - -
5 not used - -
6 not used - -
7 not used - -
Bit Function 1 0
0 Display the waste toner full
warning
YES NO