Service manual

Chapter 14
14-12
The default setting of this SSSW varies depending on the destination of the product.
Product for Japan: 00000000
Product for countries in Euro zone: 00000011
Products for other countries/regions: 00000001
14.3.12.2 Detailed Discussions of Bit 0
0011-3594
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
You can select whether a waste toner full warning is to be displayed.
When "1" is selected, a waste toner full warning is displayed.
When "0" is selected, a waste toner full warning is not displayed.
14.3.12.3 Detailed Discussions of Bit 1
0011-1767
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Select whether to display the waste toner full warning as a drum replacement required message or as E019 displayed on an operator call. Select 1 to display a rum
replacement required message on an operator call. Select 0 to display E019 on an service call.
14.4 Setting of Menu Switch (Menu)
14.4.1 Menu Switch Composition
0011-1768
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
T-14-15
14.4.2 <No.005 NL equalizer>
0011-1770
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to enable-disable the NL equalizer.
If errors occur often during communication because of the condition of the line, enable (ON) the NL equalizer.
Any of the following error codes may be indicated at time of transmission because of the line condition:
##100, ##101, ##102, ##104, ##201, ##281, ##282, ##283, ##750, ##755, ##765, ##774, ##779, ##784, ##789
Any of the following error codes may be indicated at time of transmission because of the line condition:
##103, ##107, ##114, ##201, ##790, ##793
14.4.3 <No.006 telephone line monitor>
0011-1771
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to s the telephone line monitor function:
DIAL: generate the monitor sound of the telephone line using the speaker from the start of transmission to DIS.
SERVICEMAN [1]: generate the monitor sound of the telephone line using the speaker from the start of communication to the end of it.
SERVICEMAN [2]: generate the monitor sound of the telephone line2 (Option).
OFF: do not generate the monitor sound of the telephone line using the speaker.
14.4.4 <No.007 ATT transmission level>
0011-1772
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set the transmission level (ATT).
Raise the transmission level if errors occur frequently at time of communication because of the condition of the line. (It means close to 8)
Any of the following error codes may be indicated at time of transmission because of the line condition:
##100, ##101, ##102, ##104, ##201, ##280, ##281, ##282, ##283, ##284, ##750, ##752, ##754, ##755, ##757, ##759, ##760, ##762, ##764, ##765,
##767, ##769, ##770, ##772, ##774, ##775, ##777, ##779, ##780, ##782, ##784, ##785, ##787, ##789
Any of the following error codes may be indicated at time of reception because of the line condition:
##103, ##106, ##107, ##201, ##793
1 Switch the waste toner full
warning
Drum replacement required
message displayed on an
operator call
E019 displayed on an service
call
2 Not used - -
3 Not used - -
4 Not used - -
5 Not used - -
6 Not used - -
7 Not used - -
No. Function Range of settings
005 NL equalizer 1: ON, 0: OFF
006 telephone line monitor 0:DIAL, 1:SERVICEMAN1, 2:SERVICEMAN2, 3:OFF
007 transmission level (ATT) from 0 to 15 (ex: 15= -15 dBm)
008 V.34 modulation speed upper
limit
0:3429, 1:3200, 2:3000, 3:2800, 4:2743, 5:2400
009 V34 data speed upper limit 0:33.6 kbps, 1:31.2 kbps, 2:28.8 kbps, 3:26.4 kbps, 4:24.0 kbps,
5:21.6 kbps, 6:19.2 kbps, 7:16.8 kbps, 8:14.4 kbps, 9:12.0 kbps,
10:9.6 kbps, 11:7.2 kbps, 12:4.8 kbps, 13:2.4 kbps
010 Frequency of pseudoring signal 0:50 Hz, 1:25 Hz, 2:17 Hz
Bit Function 1 0