*: Factory default
1.2.3.6 Timer Settings
0011-1227
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
*: Factory default
1.2.3.7 Report Settings
0011-1228
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
*: Factory default
1.2.3.8 Adjust./Cleaning
0011-1229
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
*: Factory default
1.2.3.9 System Settings
0011-1230
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Additional Functions Available Settings
1. DATE&TIME SETTING Default setting
2. DATE TYPE SELECT DD/MM YYYY(*), YYYY MM/DD, MM/DD/ YYYY
3. AUTO SLEEP TIME ON (3 - 30 (5(*)) MIN. in one-minute increments), OFF
4. AUTO CLEAR TIME ON (1 - 9 (2(*)) MIN. in one-minute increments), OFF
5. DAYLIGHT SV. TIME ON(*): BEGIN DATE/TIME (MONTH, WEEK, DAY), END DATE/TIME (MONTH, WEEK, DAY), OFF
Additional Functions Available Settings
1. SETTINGS TX REPORT: PRINT ERROR ONLY(*), OUTPUT YES, OUTPUT NO
RX REPORT: OUTPUT NO(*), PRINT ERROR ONLY, OUTPUT YES
ACTIVITY REPORT: AUTO PRINT (ON(*), OFF), TX/RX SEPARATE (OFF(*), ON)
2. LIST PRINT ACTIVITY REPORT
SPEED DIAL LIST: 1-TOUCH LIST, CODED DIAL LIST, GROUP DIAL LIST
ADD BOOK DETAILS: 1-TOUCH LIST, CODED DIAL LIST
USER DATA LIST
Additional Functions Available Settings
1. TRANS. ROLR CLEAN Press [OK] to start cleaning.
2. DRUM CLEANING Press [OK] to start cleaning.
3. FIX. UNIT CLEANING START CLEANING, CLEAN PAPER PRT
4. FEEDER CLEANING Set 5 sheets in the optional feeder and press [OK].
5. SPECIAL MODE M MID(*), LOW, HIGH
6. SPECIAL MODE N OFF(*), ON
7. SPECIAL MODE O DRAWER (OFF(*), ON), STACK BYPASS (OFF(*), ON)
8. SPECIAL MODE P OFF(*), ON
9. BOND SP. FIX. MODE OFF(*), ON
10. FIX. UNIT OFFSET OFF(*), SPEED PRIORITY 1, SPEED PRIORITY 2
11. AUTO ADF DRTY ADJ OFF(*), ON
12. MAINTENANCE CODE OFF(*), ON
Additional Functions Available Settings
1. SYS. MANAGER INFO SYS. MANAGER ID, SYSTEM PASSWORD, SYSTEM MANAGER
2. DEVICE INFO DEVICE NAME, LOCATION
3. MANAGE DEPT. ID OFF(*), ON; REGISTER DEPT. ID (PASSWORD, PAGE LIMIT SET., ERASE), PAGE TOTALS (VIEW PAGE
TOTALS, CLEAR ALL TOTAL, PRINT LIST), PDL JOBS W/OUT ID (ON(*), OFF)
4. MANAGE USER ID OFF(*), ON
5. NETWORK SETTINGS TCP/IP SETTINGS: IP ADDRESS AUTO. (OFF(*), ON; DHCP, BOOTP, RARP), IP ADDRESS, SUBNET MASK,
GATEWAY ADDRESS, USE LPD (ON(*); PORT NO., OFF), RAW SETTINGS (ON(*); PORT NO., USE
BIDIRECTIONAL, OFF), USB HTTP (ON(*); PORT NO., OFF), SET IP ADD RANGE (OFF(*), ON), RX MAC
ADD SET. (OFF(*), ON)
SNMP SETTINGS: USE SNMP (ON(*): PORT NO., OFF), COMMUNITY NAME 1, COMMUNITY NAME 2,
SNMP WRITABLE 1 (ON(*), OFF), SNMP WRITABLE 2 (ON, OFF(*))
DEDICATED PORT: ON(*), OFF
ETHERNET DRIVER: DETECT (AUTO(*), MANUAL), DUPLEX (HALF DUPLEX(*), FULL DUPLEX),
ETHERNET TYPE (10 BASE-T(*), 100 BASE-TX), MAC ADDRESS
VIEW IP ADDRESS: IP ADDRESS, SUBNET MASK, GATEWAY ADDRESS
STARTUP TIME SET.: 0(*) to 300 SEC.