====================================================================== Control Commands for LV series Rev1.0.4 ---------------------------------------------------------------------Updated on January 25, 2010 ---------------------------------------------------------------------This file contains information about projector control commands.
. LAN connection using the LAN port on the projector A LAN cable is required.
The control connector is described below. [ LV-7365/7265/7260/7255/7250/7245/7240 ] The SERVICE PORT is a mini DIN 8-pin port. 1 2 3 4 5 6 7 8 To TxD of PC To GND of PC To RxD of PC * 2, 3, 5, 6, and 8 are used inside the projector. [ LV-7385/7380/7285/7280/8310/8215/7375/7370/7275/8300 ] The SERVICE PORT is a D-SUB 9-pin port.
[Port Number] The TCP port number used is "7142". Supplement: (!1) LV-7385/7380/7285/7280/8310/8215/7375/7370/7275/8300 only ====================================================================== 4. List of Commands ---------------------------------------------------------------------* Example for command ---------------------------------------------------------------------Command name ---------------------------------------------------------------------001. POWER ON 002. POWER OFF 003.
032. SETTING REQUEST 033. RUNNING STATUS REQUEST 034. INPUT STATUS REQUEST 035. MUTE STATUS REQUEST 036. MODEL NAME REQUEST 037. INFORMATION STRING REQUEST 038. LAMP MODE REQUEST 039. LAMP MODE SET 040. POWER MANAGEMENT SET 041. AUTO KEYSTONE SET 042. OTHER ADJUST 043. SET PROJECTOR NAME 044. CLOSED CAPTION REQUEST 045. FAN MODE REQUEST 046. WXGA MODE SETTING REQUEST 047. CLOSED CAPTION SET 048. FAN MODE SET 049. WXGA MODE SETTING SET 050. LAMP INFORMATION REQUEST 4 051.
008. SOUND MUTE ON 009. SOUND MUTE OFF 010. ONSCREEN MUTE ON 011. LAMP INFORMATION REQUEST 012. MUTE CONTROL 013. VOLUME ADJUST Volume Bass Treble Balance 014. BASE MODEL TYPE REQUEST 015. PROJECTOR INFORMATION REQUEST 016. ERROR STATUS REQUEST 017. INFORMATION REQUEST 018. FILTER COUNTER INFORMATION REQUEST 019. LAMP INFORMATION REQUEST 3 020. TEMP INFORMATION REQUEST 021. REMOTE KEY CODE 022. FREEZE CONTROL 023. IMAGE FLIP H/V SET 024. AUTO PC EXECUTE2 025. RUNNING SENSE 026. COMMON DATA REQUEST 027.
====================================================================== 5. Command Descriptions ---------------------------------------------------------------------Description of Terms: (*1) Control ID This refers to the Control ID.
The projector does not accept the other command during power on processing. 002. POWER OFF ********************************************************************** Function: This command switches off the main power of the projector. Command: 02H 01H 00H 00H 00H 03H Response : At the time of a success 22H 01H 01H xxH 00H CKS (*1) (*2) (*3) Response : At the time of a failure A2H 01H 01H xxH 02H DATA01 DATA02 (*1) (*2) (*4) CKS (*3) Supplement: -This command will fail during switching input signal.
| 1AH | Computer2(Digital)(*5) | x| x| *| +----------------+-----------------------------------------+-----+-----+-----+ * : Supported x : Not supported ( 1) LV-X6/7260/X7 ( 2) LV-7240/7245/X5/7250/7255 ( 3) LV-7265/7365/7375/7370/7275/8300/7385/7380/7285/7280/8310/8215 Response : At the time of a success 22H 03H 01H xxH 01H DATA01 (*1) (*2) CKS (*3) Data Portion Contents ------------------------------------------------------------------DATA01 Results 00H : Normal FFH : Error (Signal select was not execu
005. INPUT SELECT S-VIDEO ********************************************************************** Function: This command switches the input terminal or input signal to S-VIDEO.
007. BLANK OFF (NO SHOW OFF) ********************************************************************** Function: This command cancels the picture muting. Command: 02H 11H 00H 00H 00H 13H Response : At the time of a success 22H 11H 01H xxH 00H CKS (*1) (*2) (*3) Response : At the time of a failure A2H 11H 01H xxH 02H DATA01 DATA02 (*1) (*2) (*4) CKS (*3) 008. SOUND MUTE ON ********************************************************************** Function: This command mutes the sound.
Response : At the time of a success 22H 13H 01H xxH 00H CKS (*1) (*2) (*3) Response : At the time of a failure A2H 13H 01H xxH 02H DATA01 DATA02 (*1) (*2) (*4) CKS (*3) 010. ONSCREEN MUTE ON ********************************************************************** Function: This command mutes the on-screen display.
DATA13 to 16 Lamp Use Prohibited Time (Normal mode) (second) Response : At the time of a failure A3H 8CH 01H xxH 02H DATA01 DATA02 (*1) (*2) (*4) CKS (*3) Supplement: Example for acquiring remaining lamp time (in terms of Normal mode values) : Lamp Hour Meter (Normal mode) DATA01 DATA02 DATA03 DATA04 30H 2AH 00H 00H : 10800 second : Starting time for lamp usage warning message (in terms of Normal mode values) DATA09 DATA10 DATA11 DATA12 00H DDH 6DH 00H : 7200000 second Lamp remaining time (in terms of
DATA01 Results 00H : Normal 01H : Error Response : At the time of a failure A2H 1AH 01H xxH 02H DATA01 DATA02 (*1) (*2) (*4) CKS (*3) Supplement: * Mute is cancelled in the following cases: Input connector switching Video signal switching Volume adjustment 013. VOLUME ADJUST ********************************************************************** Function: This command sets the volume.
A3H 10H 01H xxH 02H (*1) (*2) DATA01 DATA02 (*4) CKS (*3) Supplement: Command example: * Setting Volume to "10" 03H 10H 00H 00H 05H 05H 00H 00H 0AH 00H 27H 014. BASE MODEL TYPE REQUEST ********************************************************************** Function: This command acquires the projector type.
+-------------+-------------+-------------+-------------+----------------| FFH | 10H | 0CH | 10H | LV-7285 +-------------+-------------+-------------+-------------+----------------| FFH | 10H | 0DH | 10H | LV-7280 +-------------+-------------+-------------+-------------+----------------| FFH | 10H | 0EH | 10H | LV-8310 +-------------+-------------+-------------+-------------+----------------| FFH | 10H | 0FH | 10H | LV-8215 +-------------+-------------+-------------+-------------+----------------DATA15 to 1
10H : Signal selection in progress Other : Not Supported DATA04 Select source input type 1 01H : 1 02H : 2 03H : 3 04H : 4 05H : 5 Other : Not Supported DATA05 Select source input type 2 01H : COMPUTER (RGB) 02H : VIDEO 03H : S-VIDEO 04H : COMPONENT 05H : Reserved 06H : DIGITAL 07H : VIEWER 08H : SLOT1 09H : SLOT2 0AH : SLOT3 0BH : SLOT4 0CH : DIGITAL2 0DH : SCART 10H : AUTO FFH : Not Source Input Other : Not Supported DATA06 Indication signal type (Effective only when Select source input type 2 is 02H
* "x" means indefinite DATA07 BLANK (Picture Mute) 00H : OFF 01H : ON DATA08 Sound Mute 00H : OFF 01H : ON DATA09 On-screen mute 00H : OFF 01H : ON DATA10 FREEZE(!1) 00H : OFF 01H : ON DATA11 to DATA16 Reserved Response : At the time of a failure A0H BFH 01H xxH 02H DATA01 DATA02 (*1) (*2) (*4) CKS (*3) Supplement: (!1) LV-7385/7380/7285/7280/8310/8215/7375/7370/7275/8300 only 016.
bit1 : Temperature error(Bimetal) bit2 : None bit3 : Fan error bit4 : Fan error bit5 : Power error bit6 : Lamp(or Lamp1) error bit7 : Lamp(or Lamp1) has reached its end of life DATA02 Error Status(2) bit0 : Lamp(or Lamp1) has been used beyond its limit bit1 : Formatter error bit2 : Lamp2 error bit3 : None bit4 : None bit5 : None bit6 : None bit7 : None DATA03 Error Status(3) bit0 : None bit1 : FPGA error bit2 : Temperature error(Sensor) bit3 : Lamp(or Lamp1) housing error (!) bit4 : Lamp(or Lamp1) data e
This command acquires the projector information.
Data Portion Contents ----------------------------------------------------------------DATA01 to 04 Filter counter (second) (!) DATA05 to 08 Starting time for filter usage warning message (second)(!) Response : At the time of a failure A3H 95H 01H xxH 02H DATA01 DATA02 (*1) (*2) (*4) CKS (*3) Supplement: (!) If the model does not have filter, "-1" will be sent. 019.
(*1) (*2) (*3) Data Portion Contents ----------------------------------------------------------------DATA01 same values as DATA01 of the command DATA02 same values as DATA02 of the command DATA03 to 06 Acquired information(!1) Response : At the time of a failure A3H 96H 01H xxH 02H DATA01 DATA02 (*1) (*2) (*4) CKS (*3) Supplement: * In case of acquiring lamp counter 03H 96H 00H 00H 02H 00H 01H 9CH Example of acquisition DATA03 DATA04 50H 46H DATA05 00H DATA06 : lamp counter 00H : 18000 seconds Lamp
Function: This command acquires the information about temperature inside the projector.
Data Portion Contents ------------------------------------------------------------------DATA01 to 02 Remote control key code (Word type) Key number DATA01 DATA02 Key name -------------------------------------------1 01H 00H POWER(!1) 2 02H 00H POWER ON(!1) 3 03H 00H POWER OFF(!1) 4 04H 00H INPUT (AUTO)(!1) 5 05H 00H AUTO PC 6 06H 00H MENU 7 07H 00H UP 8 08H 00H DOWN 9 09H 00H RIGHT 10 0AH 00H LEFT 11 0BH 00H OK 12 0CH 00H BACK 13 0DH 00H INFO. 15 0FH 00H D.ZOOM UP(!1) 16 10H 00H D.
Example: Example for acquiring AUTO PC key code 02H 0FH 00H 00H 02H 05H 00H 18H Supplement: (!1) LV-7385/7380/7285/7280/8310/8215/7375/7370/7275/8300 only 022. FREEZE CONTROL ********************************************************************** Function: This command controls the freeze.
Data Portion Contents ----------------------------------------------------------------DATA01 0AH fixed DATA02 Setting Value 00H : None 01H : Rear, Ceiling mounted 02H : Rear 03H : Ceiling mounted Response : At the time of a success 23H B1H 01H xxH 02H DATA01 (*1) (*2) DATA02 CKS (*3) Data Portion Contents ----------------------------------------------------------------DATA01 0AH fixed DATA02 Results 00H : Normal 01H : Error Response : At the time of a failure A3H B1H 01H xxH 02H DATA01 DATA02 (*1) (*2) (
( Same as DATA01 of the transmit data ) Response : At the time of a failure A3H BAH 01H xxH 02H DATA01 DATA02 CKS (*1) (*2) (*4) (*3) 025. RUNNING SENSE ********************************************************************** Function: This command acquires the operation mode of the projector.
********************************************************************** Function: This command acquisition of the detailed conditions of the projector.
DATA10 to 12 DATA13 to 20 DATA21 to 28 DATA29 DATA30 DATA31 DATA32 DATA33 to 34 DATA35 to 50 DATA51 to 65 DATA66 x0H : NTSC3.58 x1H : NTSC4.43 x2H : PAL x3H : PAL60 x4H : SECAM x5H : B/W60 x6H : B/W50 x7H : PALNM x8H : NTSC3.58 LBX x9H : NTSC3.
DATA67 DATA68 DATA69 DATA70 to 71 DATA72 DATA73 DATA74 DATA75 to 82 DATA83 DATA84 DATA85 DATA86 to 128 On-screen display FFH : Not Support Selecting signal processing 00H : No execution(Normal condition) 01H : During execution Status of operation 00H : Idling 04H : Power On 05H : Cooling 06H : Idling(Error occurrence) FFH : Not Support internal use of code during a state transition period Projector type -------------++-------------+--------------+-----------------DATA01 || DATA70 | DATA71 | -----------
Response: At the time of a failure A0H C0H 01H xxH 02H DATA01 (*1) (*2) (*4) DATA02 (*3) CKS Supplement: (!1)LV-7365/7375/7370/7275/8300/7385/7380/7285/7280/8310/8215 +------------------------------------+-------------------+-----------------------| Selected input terminal | DATA07 | DATA08 +------------------------------------+-------------------+-----------------------| Computer1 | 1 (01H) | COMPUTER (01H) | Computer2(Analog) | 2 (02H) | COMPUTER (01H) | Computer2(Digital) | 2 (01H) | COMPUTER (06H) |
Data Portion Contents ----------------------------------------------------------------DATA01 to 02 Results 0000H : Normal 0000H Other : Error Response: At the time of a failure A3H 10H 01H xxH 02H DATA01 (*1) (*2) (*4) DATA02 (*3) Supplement: Command example: * Setting Brightness to 10 03H 10H 00H 00H 05H 00H FFH 00H 0AH CKS 00H 21H * Setting Brightness to -10 03H 10H 00H 00H 05H 00H FFH 00H F6H FFH 0CH 028.
Response: At the time of a failure A3H 10H 01H xxH 02H DATA01 (*1) (*2) (*4) DATA02 (*3) Supplement: Command example: * Setting Keystone to 10 03H 10H 00H 00H 05H 15H 01H 00H 0AH CKS 00H 38H * Setting Keystone to -10 03H 10H 00H 00H 05H 15H 01H 00H F6H FFH 23H 029. DISPLAY SETTINGS ADJUST ********************************************************************** Function: This command adjusts the Display settings.
Supplement: Command example: * Setting the Aspect to Wide zoom 03H 10H 00H 00H 05H 18H 00H 00H 01H 00H 31H Adjustment items Adjustment value Aspect 0000H : Normal / Auto 0001H : Wide zoom 0002H : Cinema / 16:9 0003H : True size 0004H : 4:3 0005H : 15:9 0006H : 16:10 0007H : Letterbox 030. LAMP INFORMATION REQUEST 2 ********************************************************************** Function: This command acquires lamp remaining amount.
This command acquires the adjustment values.
| 05H | 01H | Sound / Bass | 05H | 02H | Sound / Treble | 05H | 03H | Sound / Balance | 15H | 01H | Keystone V | 18H | 00H | Aspect | 97H | 00H | Screen color | 9FH | 00H | Auto iris +--------+--------+--------------------------------------+ | | | | | | |(!1) Command example: In case of acquiring Image adjustment - Brightness. 03H 04H 00H 00H 03H 00H 00H 00H 0AH (!1) LV-7285/7280 only 032.
DATA04 DATA05 DATA06 to 32 Sound function 00H : Not available 01H : Available Calendar function 00H : No function 01H or 03H : Timer function, sleep timer function function 02H : Sleep timer function Reserved Response: At the time of a failure A0H 85H 01H xxH 02H DATA01 (*1) (*2) (*4) DATA02 (*3) CKS 033. RUNNING STATUS REQUEST ********************************************************************** Function: This command acquires the status of the projector operation.
DATA07 DATA08 DATA09 to 16 internal use of code during a state transition period PC Card insertion FFH : Not Support USB Mouse connection FFH : Not Support Reserved Response: At the time of a failure A0H 85H 01H xxH 02H DATA01 (*1) (*2) (*4) DATA02 (*3) CKS 034. INPUT STATUS REQUEST ********************************************************************** Function: This command acquires the status of input signal of the projector.
DATA07 to 08 DATA09 DATA10 to 16 Reserved Indicate Contents 00H : Picture signal displaying 01H : No signal 02H : Viewer displaying 03H : Test pattern displaying 04H : LAN displaying FFH : Not Support Reserved Response: At the time of a failure A0H 85H 01H xxH 02H DATA01 (*1) (*2) (*4) DATA02 (*3) CKS 035. MUTE STATUS REQUEST ********************************************************************** Function: This command acquires the status of the mute of projector.
036. MODEL NAME REQUEST ********************************************************************** Function: This command acquires the model name of the projector.
DATA01 Classification by information type (!1) ( Same as DATA02 of the transmit data ) DATA02 Character string types ( Same as DATA03 of the transmit data ) DATA03 String length of label / information ( not including NULL character ) DATA04 to DATAxx Character string of label / information ( NULL termination character string ) Response: At the time of a failure A0H D0H 01H xxH 02H DATA01 (*1) (*2) (*4) DATA02 (*3) CKS Supplement: (!1)Information type Number Title Description ----------------------------
Function: This command sets the lamp mode of projector.
Response: At the time of a success 23H B1H 01H xxH 02H DATA01 (*1) (*2) DATA02 (*3) CKS Data Portion Contents ----------------------------------------------------------------DATA01 17H fixed DATA02 Results 00H : Normal 01H : Error Response: At the time of a failure A3H B1H 01H xxH 02H DATA01 (*1) (*2) (*4) DATA02 (*3) CKS 041. AUTO KEYSTONE SET ********************************************************************** Function: This command sets the Auto keystone.
042. OTHER ADJUST ********************************************************************** Function: This command adjusts the various gains.
0003H : Light rose 0004H : Light yellow 0005H : Light green 0006H : Sky blue 0007H : Greenboard 0008H : Greenboard(Gray) 0009H : Whiteboard (!1) LV-7285/7280 only 043. SET PROJECTOR NAME ********************************************************************** Function: This command sets projector name.
03H B0H 00H 00H 01H 09H BDH Response: At the time of a success 23H B0H 01H xxH 02H DATA01 (*1) (*2) DATA02 (*3) CKS Data Portion Contents ----------------------------------------------------------------DATA01 09H fixed DATA02 Setting Value 00H : Off 01H : Caption 1 02H : Caption 2 03H : Caption 3 04H : Caption 4 05H : Text 1 06H : Text 2 07H : Text 3 08H : Text 4 Response: At the time of a failure A3H B0H 01H xxH 02H DATA01 (*1) (*2) (*4) DATA02 (*3) CKS 045.
046. WXGA MODE SETTING REQUEST ********************************************************************** Function: This command acquires the setting of the WXGA mode of projector.
08H : Text 4 Response: At the time of a success 23H B1H 01H xxH 02H DATA01 (*1) (*2) DATA02 (*3) CKS Data Portion Contents ----------------------------------------------------------------DATA01 09H fixed DATA02 Results 00H : Normal 01H : Error Response: At the time of a failure A3H B1H 01H xxH 02H DATA01 (*1) (*2) (*4) DATA02 (*3) CKS 048. FAN MODE SET ********************************************************************** Function: This command sets the fan mode of projector.
(*1) (*2) (*4) (*3) 049. WXGA MODE SETTING SET ********************************************************************** Function: This command sets the WXGA mode of projector.
DATA02 DATA03 01H : Lamp2 Unit (!4) 00H : Second 01H : Reserved 02H : Hour Item 00H : Lamp counter (!2) 01H : Lamp counter (!3) 04H : lamp remaining amount until lamp warning message ( 100% to -X%(!1) ) 05H : Lamp counter (Normal mode) 06H : Lamp counter (Eco mode) 08H : Remaining time until lamp warning message starts to appear (in terms of specified values) 09H : Remaining time until lamp warning message starts to appear (in terms of Normal mode values) 0AH : Remaining time until lamp warning message st
(!1) X = 100 - ((Lamp Use Prohibited Time * 100) / Lamp Use Warning Starting Time) Example) The case of Lamp Use Prohibited Time 2100[H]、 Lamp Use Warning Starting Time 2000[H] Model. X = 100 - ((2100 * 100) / 2000) = -5[%] (!2) Lamp counter (in terms of Normal mode values) This is the timer for normal lamp mode conversion. (!3) Lamp counter This is the lamp total usage. It is displayed in the projector's menu. (!4) This setting is ignored, if the Item's unit is not time. 051.
Total Carbon Savings = (2460 * 1000) + (63750 / 1000) = 2460063.75 [g] = 2460 + (63750 / 1000 / 1000) = 2460.06375 [kg] ====================================================================== 6. Response ---------------------------------------------------------------------* At the time of a success: This returns ACK without adding data portion to the command that does not request data. This returns ACK with adding data to the data portion for the command that requests data.