LV-X4 SERIAL FUNCTIONAL SPECIFICATION History of Modification Rev. Contents New Document Date 2004.08.
SERIAL FUNCTIONAL SPECIFICATION CONTENT 1. Overview ....................................................................................................................... 4 2. Interface Specification.................................................................................................. 4 3. Connection .................................................................................................................... 4 4. Notes for Communication............................................
SERIAL FUNCTIONAL SPECIFICATION 8. 7.31. ON Start Setting Command .............................................................................. 11 7.32. ON Start Cancellation Command ..................................................................... 11 7.33. Power Management Ready Command .............................................................. 11 7.34. Power Management OFF Command................................................................. 11 7.35.
SERIAL FUNCTIONAL SPECIFICATION 1. Overview 1.1. This Specification defines projector control commands for LV-X4 (0.8”XGA model). 1.2. The projector control commands are for controlling projector through RS232C from a computer. 2. Interface Specification Item Shynchro system Transmission Speed Data Length Parity Stop Bit Flow Control Specification Asynchronous 9600 / 19200 8 bit None 1 None 1. Transfer rate: initial setting value is 19200 2. Transfer rate can be changed by service mode 3.
SERIAL FUNCTIONAL SPECIFICATION 4. Notes for Communication 4.1. The projector command is defined one command/one line that starts “C” and ends carriage return (0x0D). 4.2. The projector starts decoding after the carriage return. 4.3. There are two types of command, functional execution commands and state read commands. Example of Functional Execution Command: “C05” [CR] Example of State Read Command: “CR0” [CR] 4.4. It clears information of accepting buffer as following terms. 1.
SERIAL FUNCTIONAL SPECIFICATION 5. Functional Execution Command Table Command 6. Item Command Item C00 Power ON C2A Power Management Ready C01 Power OFF (Quick Power OFF) C2B Power Management OFF C02 Power OFF C2E Power Management Shut down C05 Computer 1 C30 D.Zoom + C06 Computer 2 C31 D.
SERIAL FUNCTIONAL SPECIFICATION 7. Functional Execution Command 7.1. Format 1. PC issues a command as below form at “C” COMMAND [CR] COMMAND: 2 characters (See Functional Execution Command Table) 2. A projector decodes received data and sends a return result after being ready to receive next command. [ACK] [CR]: (0x06, 0x0D) When received functional execution commands. “?” [CR]: When cannot read received data. 7.2.
SERIAL FUNCTIONAL SPECIFICATION 7.5. Power ON Command Command Detail Response 7.6. Power OFF Command (Quick Power OFF) Command Detail Response 7.7. “C01” [CR] Power OFF (Standby) When Power OFF with POWER button of the projector or the remote control, “Power OFF” will be displayed. However, as soon as this command is sent, Quick Power OFF is executed. Acceptable [ACK] [CR] Unacceptable “?” [CR] Power OFF Command Command Detail Response 7.8.
SERIAL FUNCTIONAL SPECIFICATION 7.12. Volume - Command Command Detail Response 7.13. Audio Mute ON Command Command Detail Response 7.14. Detail Response Detail Response Detail Response Response “C0F” [CR] Set video screen size to Normal (4:3) Acceptable [ACK] [CR] Unacceptable “?” [CR] Screen Wide size Command Command Detail Response Item “C0E” [CR] Video Mute OFF This command works the same as “NO SHOW” of the remote control for Video Mute OFF, but does not work for “No Show ON”.
SERIAL FUNCTIONAL SPECIFICATION 7.19. Image_ Standard Command Command Detail Response 7.20. Image_ High contrast Command Command Detail Response 7.21.
SERIAL FUNCTIONAL SPECIFICATION 7.28. Brightness - Command Command Detail Response 7.29. Computer 2_ RGB Command Command Detail Response 7.30. Detail Response Detail Response Detail Response Detail Response Detail Response “C2B” [CR] Set Power Management to OFF mode. This status is stored in EEPROM, so even if turning off and on. Acceptable [ACK] [CR] Unacceptable “?” [CR] Power Management Shut down Command Command Detail Response Item “C2A” [CR] Set Power Management to Ready mode.
SERIAL FUNCTIONAL SPECIFICATION 7.36. D.Zoom + Command Command Detail Response 7.37. D.Zoom - Command Command Detail Response 7.38. Response Response Response Detail Response Detail Response “C3B” [CR] Move Pointer to right On Screen Display. This command works the same as the Remote Control’s “<” button. Acceptable [ACK] [CR] Unacceptable “?” [CR] Pointer Up Command Command Detail Response Item “C3A” [CR] Move Pointer to right On Screen Display.
SERIAL FUNCTIONAL SPECIFICATION 7.44. Pointer Down Command Command Detail Response 7.45. Mouse Right Click Command Command Detail Response 7.46. Detail Response Detail Response Detail Response Response Response “C51” [CR] Select Computer-1 of Scart input. Acceptable [ACK] [CR] Unacceptable “?” [CR] Computer 1_ Component Command Command Detail Response Item “C50” [CR] Select Computer-1 of Analog RGB input. Acceptable [ACK] [CR] Unacceptable “?” [CR] Computer 1_ Scart Command Command Detail 7.
SERIAL FUNCTIONAL SPECIFICATION 7.52. Page Up Command Command Detail Response 7.53. Page Down Command Command Detail Response 7.54. Detail Response Detail Response Response “C8E” [CR] Adjust keystone. Make the screen image length at the top edge shorter. Acceptable [ACK] [CR] Unacceptable “?” [CR] Keystone↓ Command Command Detail Response Item “C8A” [CR] Set a presentation timer to active. This command works the same as the remote control’s “P-TIMER” button.
SERIAL FUNCTIONAL SPECIFICATION 8. Status Read Command 8.1. Format 1. A PC issues commands fin format as below. “CR” COMMAND [CR] COMMAND: 1 character (See Status Read Command Table) 2. When a projector receives the appropriate command, it returns a character line as the required data. Required Data [CR] Required Data: A character line (See Status Read Command Table) 3. 8.2. When receiving data cannot be decode, the projector returns, “?” [CR].
SERIAL FUNCTIONAL SPECIFICATION 8.3.2. “80” [CR] Status: Standby When the status is Standby, Status Read Commands are always acceptable, but Functional Execution Commands are not acceptable except Power ON Command. 8.3.3. “40” [CR] Status: Processing Count down When “Display” in Setting Menu is ON and Power ON is executed, it starts processing Count Down. When “Display” OFF in the setting menu is set, processing Count Down is skipped and the status moves to Power ON quickly. 8.3.4.
SERIAL FUNCTIONAL SPECIFICATION 8.3.9. “02” [CR] Status: RS232C Command is unacceptable When a computer receives this response, try to execute Status Read Command again. 8.3.10. “24” [24] Status: Processing cooling down by power save When Power Management function is ON in setting menu and there is no signal for 5 minutes, it moves on to Power Save/Cooling Down after tuning off the lamps. (During this process, Green LED is OFF) The control command is invalid.
SERIAL FUNCTIONAL SPECIFICATION 8.4. Input Mode Read Command Command Detail Response 8.5. Lamp Time Read Command Command Detail Response 8.6.