Technical information

11. Removing the Upper Separation
Claw
1)
Open the delivety unit.
2
Mark the
position
of the upper separation
claw
retainer using a scriber.
3) Removethe three mountingscrews, and remove
the upper separation
claw
retainer; be careful
with the delivety detection lever at the time.
@
Mounting screws
@
Upper separation claw retainer
@
Delivery detection lever
Figure 4-102
4) Remove the spring, and remove the upper
separation
claw.
12. Mountingthe Upper Separation Claw
Reverse the steps above to mount the upper
separation
claw
with the following
in
mind:
-
Keep the upper separation claw unit to the rear;
if a scar
is
made on the upper fixing roller, mount
the
claw
about 4 mm displaced to the front.
13. Removing the Lower Separation
Claw
1)
Open the
delivery
unit.
2) Slidethelowerseparationguideplatetoremove.
@ Lower separation guide plate
Figure 4-103
3) Remove the spring, and
remove
the lower
separation
claw.