Technical information

MAINTENANCE AND
SERVICING
tZZi?B
Note:
1.
As a rule, conduct the following
wok
every 20,000 copies.
2.
Check the service
record
before
paying a
vis%,
and take replacement parts if necessary.
;tep
Work
Checks
Remarks
1
Meet the operator. Check the condition.
2
Record the counter reading. Check the faulty copies.
3
Make test
copiers;
in
the DIRECT,
Check the following:
REDUCE, ENLARGE, page a. image for density
separation modes.
b. background for dirl
c. characters for
clarity
Standards:
d. leading edge for margin
1.5
fo.5
mm/0.061t0.02
in
e.
left
and right
sides
for
(DIRECT)
margin
Standards:
1.
fixing, registration, and
2.5
el.5
mm/0.1+0.06
in
back
of copy for
dirt
(DIRECT)
g.
abnormal
sound
h. counter operation
4
Clean
the corona units.
Dry wipe the units using
lint-
free paper; thereafter,
clean
them using
an
alcohol
solution. Do not set unless dn
5
Clean
the static eliminator and
Clean
the
eliminator
using
the
feeder
unit.
cleaning brush (accessory).
6
Clean
the fixing
unit
and delivery
unit:
-
paper
guide
plate
Use a solvent.
-
separation
claw
(upper, lower)
Use a solvent.
0
static eliminator (brush)
7
Conduct periodical
servicing
according to the number of copies
processed;
see
p.
6-4.
8
Clean
the copyboard cover and
copyboard
glass.
9
Make
test
copies.
10
Make sample copies.
11
Put the sample copies
in
order, and
clean
up the
area
around the
copier.
12
Record the counter reading.
13
Fil1
out
the Service Sheet, and reporl
to the operator.
COPYRIGHT
8
1992 CANON ING.
CANON
NPZl20/2MO
RN.1
JAN. 1592 PAINTEO IN JAPAN [IMPRIME
AU
JAPON)
6-3