Technical information

@
Adjusting the AE Slope
1)
Remove the Test Sheet, place a newspaper
on
the copyboard, and
close
the copyboard cover.
2) Press the SORTIGROUP key
on
the control
panel.
*
The copier operates as
in
step 5) of “Adjusting
the
AE
Referente Point.”
3) Take notes of the value shown on the copy
counter of the control panel.
4) Press the SORT/GROUP key
on
the control
panel.
-
The copy counter on the control panel
will
indicate
‘0’.
5)
Enter ‘1’ on the tenkey pad on the control panel.
-
The copy counter on the control panel
will
indicate ‘1’.
6) Press the SORTIGROUP key.
7) Turn VR2
(AE
slope)
on
the adjusting PCB so
that the value
on
the copy counter of the control
panel
is
the
same
as the value
recorded
in
step
3)
Document
denslty
Test
Sheet Newspaper
Figure 3-33
8)
Press the SORT/GROUP key after making
ad-
justments.
9) Press the push switch (SWI) on the
adjusting
PCB
Blank
Figure 3-34 Adjusting PCB
COPYAIGHT
@
1992 CAllON INC. CANON
NPZlZO/ZMO
RN.0 MAY 1990 PRIHTEO IN JAPAH IIMPAIME
AU
JAPONI
3-35