Specifications

CHAPTER 11 TROUBLESHOOTING
COPYRIGHT
©
1999 CANON INC. CANON NP6512/6612/7120/7130/7130F REV.0 AUG. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
11-49
7. Current Correction for Measurement of APVC (IP_ADJ)
Perform this adjustment whenever you have replaced any of the following parts:
DC controller PCB
Composite power supply PCB
Making Adjustments
If you have replaced the DC controller PCB,
1) Select '35' in service mode.
The display will indicate '35'.
2) Press the Copy Start key.
The existing setting will flash.
3) Enter the value of 'IP_ADJ' recorded on the service label using the +/- key.
4) Press the AE key to store the new setting.
• If you have replaced the composite power supply PCB,
1) Select '35' in service mode.
The display will indicate '35'.
2) Press the Copy Start key.
The existing setting will flash.
3) Enter the value of 'IP_ADJ indicated on the new composite power supply PCB using the +/-
key.
120V 230V
34
PW
OFST
35
IP
ADJ
Composite power supply PCB
Figure 11-267
4) Enter the AE key to store the new setting.
5) Record the new value on the service label.