User Guide

SERVICE BULLETIN
FAX
Issued by Canon Europa N.V.
MODEL:
SmartBase PC1210D
No.:
PC1200S-014
SmartBase PC1230D
(FF-T01-L6-000049-01)
Date: 25.10.02
LOCATION: INTERNAL COMPONENTS 3
SUBJECT: CHANGE OF A PART
Reason :
Measure to prevent the grounding plate 3 (reader unit) from lifting
Measure to prevent the grounding plate (FB6-0101) of the reader unit from coming
into contact with other parts.
Outline :
As a permanent measure, double-sided adhesive tape is affixed to the grounding
plate (FB6-0101), so that the plate will be secured firmly without being lifted. With
this change, the components of the grounding plate are changed.
With the modification described above, the grounding plate is changed from FB6-
0101 to FF6-1455 (consists of FB6-0101 and FB6-0092).
Service part remains unchanged. Refer to Service Bulletin PC1200S-015.