User Guide

SERVICE BULLETIN
COPIER
Issued by Canon Europa N.V.
MODEL:
PC1230, PC1270
No.:
PC-004 Rev. 1
(FF-T01-L6-000019-01
Date: 20.12.02
LOCATION: ADF ASSEMBLY
SUBJECT: CHANGE OF SHAPE
Reason :
Measure for the document feed failure
Outline :
A. The ribs on the back of the pad mount of the registration lower guide
(FL2-0005) are extended so that the pad mount will not be displaced from the
home position even if the pad mount unit is pressed forcefully. (Indicated by the
arrow in the figure)
B. The rib on the retaining part of the document sensor arm is extended so that
the retaining part will be prevented from bending and the sensor arm will not
come off even if it is pressed forcefully. (Enlarged illustration)
Parts
Part Name Part No. UNIT No. Qty IC Location
Old GUIDE,REGISTRATION
LOWER
FL2-0005-000 1 NY
New GUIDE,REGISTRATION
LOWER
FL2-0005-000 1

Summary of content (2 pages)