11
Installing the Batteries
Recycling Time and Flash Count
Battery Type Recycling Time Flash Count
Size-AA alkaline batteries Approx. 0.1-7.5 sec. Approx. 200-1400
• Use four new batteries of the same type. When replacing batteries, replace all
four batteries at one time.
• Size-AA lithium batteries can also be used.
• Although non-alkaline, manganese batteries may also be used, the number of
flashes will be less.
• Remove the batteries when the 420EX will not be used for an extended period.
• In low temperatures, take two sets of batteries and keep one set warm in a
pocket, etc., and use the batteries alternately.
• An external power pack cannot be used with the 420EX.
• The above specifications are based on Canon’s testing standards.
• Using size-AA nickel-hydride batteries will yield only about 70 to 80
percent of the flashes (1550 mAh at full output) obtainable with size-AA
alkaline batteries. The recycling time will also be about half the time with
size-AA alkaline batteries.
• To prevent faulty connections, make sure the battery contacts are clean. If
necessary, use a clean cloth to wipe the battery contacts.
• In the case of size-AA nickel-hydride and size-AA lithium batteries, the shape
of the contacts is not standardized. Be sure that the batteries are compatible
with the flash unit before buying.