Network Video Recording Software RM Series Administrator’s Manual

126
Error Codes
Winsock Error Codes
SMTP Error Codes
Code Error Message Possible Cause
10038 An operation was attempted on something that is not a
socket.
This may occasionally occur. No action is required.
10048 Only one usage of each socket address (protocol/network
address/port) is normally permitted.
All communication resources are in use. This error is
frequently reported when a video can no longer be displayed
in a Viewer layout sequence.
10050 A socket operation encountered a dead network. Occurs when the computer recognizes that the network is
down because the router or hub closest to the computer is
powered off. Normally, this cannot be recognized, therefore
this error is rarely reported.
10051 A socket operation was attempted to an unreachable
network.
Occurs when other network devices recognize that the
network is down because the router or hub is powered off.
Normally, this cannot be recognized, therefore this error is
rarely reported.
10054 An existing connection was forcibly closed by the remote
host.
The connection was aborted by the camera due to a camera
restart or other causes. This may occur when the camera is
restarted using the restart button on the Setting Page
provided by the camera software. However, this rarely
occurs.
10060 A connection attempt failed because the connected party
did not properly respond after a period of time, or
established connection failed because connected host has
failed to respond.
A timeout occurred in the TCP connection with the camera.
This occurs when the camera is powered off.
10061 No connection could be made because the target machine
actively refused it.
The camera rejected the TCP connection. This occurs when
the port number is incorrect or from another cause.
10064 A socket operation failed because the destination host was
down.
Occurs when the camera is powered off. Normally, 10060
occurs.
10065 A socket operation was attempted to an unreachable host. There is no route for connecting to the camera. This may also
occur when there is a failure in the network cable connected
to the computer or hub.
10091 WSAStartup cannot function at this time because the
underlying system it uses to provide network services is
currently unavailable.
There is a failure on the computer’s network adapter.
11001 No such host is known. The host name could not be resolved in the DNS.
11004 The requested name is valid, but no data of the requested
type was found.
The host name could not be resolved in the DNS.
Code Error Message Possible Cause
421 <domain> Service not available, closing transmission
channel
The communication was terminated because the mail server
was stopped.
450 Requested mail action not taken: mailbox unavailable The requested mail processing was not performed because
the mailbox is not available.
451 Requested action aborted: local error in processing The requested operation was canceled because an error
occurred in the mail server.
502 Command not implemented The mail server does not support the command that was
sent.
550 Requested action not taken: mailbox unavailable The request was not executed because the mailbox is not
available.