Specifications

WITE32 Release Notes Version 3.20
14. In the Gated Stability mode the Amplitude Stability and the Pulse Width Stability tests set the write gate
wrongly – full size instead of 50% of a full size – if the Always Full Size option is enabled in the
Control | Gate and Track Format dialog.
15. The Spectrum Analyzer frequency response correction was applied only to the Spectrum Analyzer,
Spectral SNR, and Spectral Integral SNR tests. The Spectrum Analyzer frequency response correction
was not applied to the TAA, TAA Asymmetry, Track Profile, and Triple Track tests, when they were
configured to use the overwrite filter. Now all tests, which perform TAA measurements through the
Spectrum Analyzer, utilize the Spectrum Analyzer frequency response correction.
Note: The Spectrum Analyzer frequency response correction is designed to compensate the non-flatness of the
spectrum analyzer frequency response in the range of working frequencies. When engaged, it automatically
multiplies the results of the amplitude measurements performed through the spectrum analyzer by the
correction coefficient, which corresponds to the current spectrum analyzer working frequency.
5.6 Miscellaneous
1. In the Serial Numbers dialog box the previous shortcuts are restored: "Alt + H" for Heads and "Alt + E"
for Head Stacks.
2. The Filter configuration form (Control | Filter) displays the last eight positions of a cutoff frequency
value for programmable filters. If the value has many digits after the decimal point, the Cutoff Freq
textbox truncates the most significant digits. In the current revision of WITE32 the Cutoff Freq value
for low path filters or programmable differentiators is rounded to four digits after the decimal point.
3. It is possible to disable all sectors in the Control | Gate and Track Format dialog. No measurements can
be preformed in this case.
4. Pattern Editor (PE32.EXE) application cannot import a file, which name contains spaces, when the file
name is passed as a parameter in a command line.
5. Pattern Editor (PE32.EXE) application: in the case of multi-line error message, only the first line of
error message is displayed
6. When WRESULT.EXE module runs as a standalone application to show history database content,
statistic results are displayed as raw results.
7. If an executable external module takes a long time to complete the initialization, WITE32 terminates
the module.
8. Custom written WDK executable modules do not apply MR-Impedance calibration (Calibration | MR-
Impedance…) for MR-Impedance measurement.
9. If the Dashboard Band Erase configuration is changed, WITE32 does not prompt user to save
configuration during termination.
10. If the Use System Setup option in the Dashboard Band Erase configuration is enabled, the band erase
Setup button on the Dashboard becomes disabled. Hence, there is no way to change the settings.
11. An error message "Download error: PLO4000: no acknowledgment of successful program download"
pops up intermittently on WITE32 loading.
62 Guzik Technical Enterprises