Manual
Table Of Contents
- 1 Features and Specifications
- 1.1 Overview
- 1.2 Features
- 1.3 Specifications
- 1.3.1 NVR100/100-P Series
- 1.3.2 NVR11/11-P Series
- 1.3.3 NVR11H/11H-P Series
- 1.3.4 NVR11HS Series
- 1.3.5 NVR41/41-P/41-8P/41-W Series
- 1.3.6 NVR41H/41H-P/41H-8P Series
- 1.3.7 NVR42/42-P/42-8P Series
- 1.3.8 NVR42-4K/42-8P-4K Series
- 1.3.9 NVR44/44-8P/44-16P Series
- 1.3.10 NVR44-4K Series
- 1.3.11 NVR48-4K Series
- 1.3.12 NVR48/48-16P Series
- 1.3.13 NVR72/72-8P Series
- 1.3.14 NVR74/74-8P/74-16P Series
- 1.3.15 NVR78/78-16P/78-RH Series
- 1.3.16 NVR70/70-R Series
- 1.3.17 NVR42V-8P Series
- 2 Front Panel and Rear Panel
- 2.1 Front Panel
- 2.1.1 NVR11/11-P/41/41-P/41-W Series
- 2.1.2 NVR11H/11H-P/41H/41H-P/41H-8P Series
- 2.1.3 NVR11HS Sereis
- 2.1.4 NVR41-8P Series
- 2.1.5 NVR42/42-P/42-8P/72/72-8P Series
- 2.1.6 NVR42-4K/42-8P-4K/44-4K/48-4K Series
- 2.1.7 NVR44/44-8P/44-16P/74/74-8P/74-16P Series
- 2.1.8 NVR48/48-16P/78/78-16P Series
- 2.1.9 NVR78-RH Series
- 2.1.10 NVR70/70-R Series
- 2.1.11 NVR42V-8P Series
- 2.2 Rear Panel
- 2.2.1 NVR100/100-P Series
- 2.2.2 NVR11/11-P Series
- 2.2.3 NVR41/41-P/41-8P/41-W Series
- 2.2.4 NVR11H/11H-P/41H/41H-P/41H-8P Series
- 2.2.5 NVR11HS Series
- 2.2.6 NVR42/42-P/42-8P Series
- 2.2.7 NVR42-4K Series
- 2.2.8 NVR42-8P-4K Series
- 2.2.9 NVR44/44-8P/44-16P Series
- 2.2.10 NVR44-4K/48-4K Series
- 2.2.11 NVR48/48-16P Series
- 2.2.12 NVR72 Series
- 2.2.13 NVR72-8P Series
- 2.2.14 NVR74 Series
- 2.2.15 NVR74-8P/74-16P Series
- 2.2.16 NVR78 Series
- 2.2.17 NVR78-16P Series
- 2.2.18 NVR78-RH Series
- 2.2.19 NVR70 Series
- 2.2.20 NVR70-R Series
- 2.2.21 NVR42V-8P Series
- 2.3 Alarm Connection
- 2.4 Bidirectional talk
- 2.5 Mouse Operation
- 2.1 Front Panel
- 3 Device Installation
- 3.1 Check Unpacked NVR
- 3.2 About Front Panel and Rear Panel
- 3.3 HDD Installation
- 3.3.1 NVR100/100-P Series
- 3.3.2 NVR11/11-P/41/41-P/41-8P/41-W Series
- 3.3.3 NVR11H/11H-P/41H/41H-P/41H-8P/11HS Series
- 3.3.4 NVR42/42-P/42-8P/72/72-8P/42-4K/42-8P-4K Series
- 3.3.5 NVR44/44-8P/44-16P/74/74-8P/74-16P/44-4K Series
- 3.3.6 NVR48/48-16P/NVR78/78-16P/48-4K Series
- 3.3.7 NVR78-RH Series
- 3.3.8 NVR70/70-R Series
- 3.3.9 NVR42V-8P Series
- 3.4 CD-ROM Installation
- 3.5 Connection Sample
- 3.5.1 NVR100/NVR100-P Series
- 3.5.2 NVR11/11-P/41/41-P/41-8P/41-W Series
- 3.5.3 NVR11H/11H-P/41H/41H-P/41H-8P Series
- 3.5.4 NVR11HS Series
- 3.5.5 NVR42/42-P/42-8P Series
- 3.5.6 NVR42-4K Series
- 3.5.7 NVR42-8P-4K Series
- 3.5.8 NVR44-4K/48-4K Series
- 3.5.9 NVR44/44-8P/44-16P Series
- 3.5.10 NVR48/48-16P Series
- 3.5.11 NVR72 Series
- 3.5.12 NVR72-8P Series
- 3.5.13 NVR74 Series
- 3.5.14 NVR74-8P/74-16P Series
- 3.5.15 NVR78 Series
- 3.5.16 NVR78-16P Series
- 3.5.17 NVR78-RH Series
- 3.5.18 NVR70 Series
- 3.5.19 NVR70-R Series
- 3.5.20 NVR42V-8P Series
- 4 Local Basic Operation
- 4.1 Boot up and Shutdown
- 4.2 Startup Wizard
- 4.3 Navigation Bar
- 4.4 Smart Add
- 4.5 Remote Device
- 4.6 Preview
- 4.7 PTZ
- 4.8 Record and Snapshot
- 4.9 Playback and Search
- 4.10 Backup
- 4.11 Alarm
- 4.12 Network
- 4.12.1.1 TCP/IP
- 4.12.1.2 Connection
- 4.12.1.3 WIFI AP
- 4.12.1.4 WIFI
- 4.12.1.5 3G
- 4.12.1.6 PPPoE
- 4.12.1.7 DDNS Setup
- 4.12.1.8 UPnP
- 4.12.1.9 IP Filter
- 4.12.1.10 Email
- 4.12.1.11 FTP
- 4.12.1.12 SNMP
- 4.12.1.13 Multicast
- 4.12.1.14 Alarm Centre
- 4.12.1.15 Auto register
- 4.12.1.16 P2P
- 4.12.1.17 Easy Space
- 4.12.1.18 SWITCH
- 4.12.2 Network Test
- 4.13 HDD Setup
- 4.14 Basic Setups
- 4.15 Device Maintenance and Manager
- 5 Web Operation
- 5.1 General Introduction
- 5.2 LAN Mode
- 5.3 Real-time Monitor
- 5.4 PTZ
- 5.5 Image/Alarm-out
- 5.6 Zero-channel Encode
- 5.7 WAN Login
- 5.8 Setup
- 5.9 Information
- 5.10 Playback
- 5.11 Alarm
- 5.12 Log out
- 5.13 Un-install Web Control
- 6 Glossary
- 7 FAQ
- 8 Appendix A HDD Capacity Calculation
- 9 Appendix B Compatible Network Camera List
83
Figure 2-49
Note
There are two alarm input types: NO/NC.
When connect the ground port of the alarm device to the NVR, you can use any of the GND ports
(
).
Connect the NC port of the alarm device to the alarm input port (ALARM) of the NVR.
When there is peripheral power supplying for the alarm device, please make sure it is earthed with
the NVR.
2.3.3 Alarm input and output port
There is peripheral power supplying for the external alarm device.
In case overload may result in NVR damage, please refer to the following relay specifications for
detailed information.
A/B cable of the RS485 is for the A/B cable connection of the speed PTZ.
2.3.4 Alarm relay specifications
Model:
JRC-27F
Material of the
touch
Silver
Rating
(Resistance
Load)
Rated switch capacity
30VDC 2A, 125VAC 1A
Maximum switch power
125VA 160W
Maximum switch voltage
250VAC, 220VDC
Maximum switch currency
1A
Insulation
Between touches with same
polarity
1000VAC 1minute