ELECTRICAL WIRING INSTALLATION (cont’d):
STEP 1: ELECTRICAL INSTALLATION
STANDARD WIRING (FOUR WIRE CONNECTION)
1. Each wire must be individually connected to the household supply wire.
2. Connect the Green appliance ground wire to the Green household ground wire from the junction box.
3. Connect the appliance Black L1 wire to the household Black L1 wire from the junction box.
4. Connect the appliance White Neutral wire to the household White neutral wire from the junction box.
5. Connect the appliance Red L2 wire to the household Red L2 wire from the junction box.
DEVIATIONS FROM STANDARD WIRING (MUST COMPLY WITH LOCAL CODES):
1. Three Wire Connection – Must be permitted by local codes
a. Each wire must be individually connected to the household supply wire.
b. Connect the appliance Black L1 wire to the household Black L1 wire from the junction box.
c. Connect the appliance White Neutral wire and the Green appliance wire to the household White
neutral wire from the junction box.
d. Connect the appliance Red L2 wire to the household Red L2 wire from the junction box.
2. Three Wire Connection with External Ground – Must be permitted by local codes
a. Each wire must be individually connected to the household supply wire.
b. Connect the appliance Black L1 wire to the household Black L1 wire from the junction box.
c. Connect the appliance White Neutral wire to the household White neutral wire from the junction
box.
d. Connect the appliance Red L2 wire to the household Red L2 wire from the junction box.
e. Connect the Green appliance ground wire to an approved external ground source, such as a cold
water pipe. (All ground sources must be approved by local codes).
WARNING:
An external ground may only be used if local codes permit.
Ground sources must be approved by local codes.
Do not connect the ground wire to a gas or hot water pipe.
Use a separate copper wire when installing with an external ground.
A clamp type connector with an external grounding screw is to be used with a minimum No. 10
copper wire when utilizing an external ground.
The approved ground source must have continuity to electrical ground and cannot be interrupted by
insulating materials.
If an interruption or insulating material is in line of the ground source it must be jumpered with a 4
gauge minimum wire.
IMPORTANT: Save these instructions for the Local Gas Inspector's use.
INSTALLER: Please leave these Installation Instructions with the unit for the owner.
OWNER: Please retain these instructions for future reference.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of
local codes, with the National Electrical Code, ANSI/NFPA 70
ALL OPEN BURNER RANGES ARE EQUIPPED WITH SMALL PAN BURNER AT THE BACK LEFT, THE
OTHERS BURNERS ARE RATED AT 23,000 BTU / HR