VERTICAL JET PUMPS FW0636 0413 INSTALLATION INSTRUCTIONS & PARTS MANUAL IL0319 “VA” SERIES 1/2 - 1-1/2 HP FULLY AUTOMATIC CONTROL VALVE 3/4 - 1-1/2 HP TWO STAGE IL0316 Supersedes 0909 IL0435 “VS” SERIES 1/2 - 1-1/2 HP SEMI AUTOMATIC CONTROL VALVE 3/4 - 1-1/2 HP TWO STAGE “VPH” SERIES - 1 HP SEMI AUTOMATIC CONTROL VALVE 1 HP SINGLE STAGE “VS” SERIES 1/2 - 1-1/2 HP HORIZONTAL POSITION USING OPTIONAL 135276 PUMP BASE EJECTORS AND ADAPTERS L0195 Single pipe ejector, leather packers for 2” wells ST
MOTOR SPECIFICATION CHART NAMEPLATE PUMP MOTOR TAPPING SIZE INCHES DIMENSIONS INCHES MAX AMPS MODEL HP STG. CONNECTED NO. FOR 115V 230V DISCHG. SUCTION PRESS. H W L WT. VS207P 3/4 2 18 9 230V 1” 1-1/4” 1” 17” 9-1/4” 15-1/8” 67 lb. VA207P VPH10 1 1 18 9 230V 1” 1-1/4” 1” 15-1/2” 6-1/2” 14-1/2” 56 lb. VS210P 1 2 21 10.5 230V 1” 1-1/4” 1” 17-5/8” 9-1/4” 15-1/8” 72 lb. VA210P VS215P 1-1/2 2 25 12.5 230V 1” 1-1/4” 1” 18-1/8” 9-1/4” 15-1/8” 76 lb. All motors are single phase 60 Hz., 3450 RPM.
PRELIMINARY CONSIDERATIONS V. Well To Pump Piping A. All offset piping should slope upwards from well to pump. B. Avoid dips or pockets in offset piping, or air will accumulate at high points and make priming difficult. C. Install unions at pump and at well to aid in servicing. D. Allow enough room around pump and piping installation for using pipe wrenches, and for service and installation. E. Do not use piping of sizes smaller than those listed in Chart 1, or pump will not operate properly. I.
II. Deep Well (Single Pipe System) Application - Where the inside diameter of well is 2, 2-1/2 or 3 inches (See Illustration A & B). A. Attach foot valve directly to bottom of ejector assembly (tail pipe not used on single pipe installations). Ejector is to be submerged 10 to 15 feet below pumping water level, making certain foot valve is at least five feet from bottom of well. B. Attach foot valve and packer ejector to suction pipe (presoak packer leathers for approximately two hours).
F. The pressure switch is wired to the motor by connecting the motor lead to the two inside terminals of the pressure switch. Connect the power lines to pressure switch terminals marked L-1 and L-2. AVERAGE OPERATING PRESSURE MODEL NO. SETTING VS, VA207P Motor Lo ad ad Lo Line 1 PRESSURE 3/4 46 PSI VS, VA210P 1 57 PSI VS, VA215P 1-1/2 72 PSI VPH10 1 47 PSI NOTE: PUMP WILL NOT PRIME IF THERE IS ANY LEAKAGE IN THE SUCTION PIPING. III. Pumps Installed In A Horizontal Position A.
MOTOR REPLACEMENT E. Install the new rotary seal assembly: 1. I nsert the ceramic seal and the rubber gasket into the recess. N OTE: To help facilitate installation, apply a light coating of oil to the outside diameter of the rubber gasket. Make certain that the ceramic seal is kept clean and free of dirt and/or oil. 2. S lip the remaining parts of the rotary seal assembly onto the motor shaft. NOTE: Apply a light coating of oil to the inside diameter of the rubber drive ring. F.
DEEP WELL JET PUMP REPAIR PARTS “VA”, “VS” & “VPH” SERIES FORM NO. FW0035 0413 SUPERSEDES 1009 PAGE 3-1A REPAIR PARTS (For Pricing Refer To Repair Parts Price List) “VA” “VS” 1 1 2 13 13 10 10 3 IL0319 14 IL0316 14 11 4 12 5 6 “VPH” 7 1 8 5 13 7 10 9 10 14 IL0426 12 ITEM DESCRIPTION 1 Motor, Nema J (Thd) Motor Cover w/screws Screws Cover Motor Lead Wire Shaft Mounting Ring Hex Hd.
Priming Port Priming Port Priming Port Pump Pump Pump Gasket Gasket Right Angle Well Adapter Gasket Straight Adapter Suction Pipe Suction Pipe Well Casing Pressure Pipe Well Seal Suction Pipe Pressure Pipe Well Casing Single Pipe Ejector Foot Valve Illustration (A) Single Pipe Over the Well Installation Double Pipe Ejector Single Pipe Ejector Tail Pipe Foot Valve Foot Valve Illustration (C) Double Pipe Over the Well Installation Illustration (B) Single Pipe Offset Installation IL1708